60 AXN Quick Start Kit User Guide (BK/0045 | 9 Aug. 2021)
3
The package is added to the
Package Properties
pane..
Rename the package if required.
Set
Stream ID
to the required value (it must be a unique Hex value between 0 and FFFFFFFF).
Source IPA
should match the IP address of the AXN/BCU/40x.
Source UDP Port
is editable.
Destination MAC
is automatically calculated based on
Destination IPA
address for multicast IP.
Making the
Destination IPA
address Unicast enables editing of the
Destination MAC
.
Destination UDP
port is editable.
The
Rate
setting for the package is the most important setting. All parameters placed in this packet are
sampled at this rate multiplied by the number of samples in the packet. For example, a parameter placed once
in a 10-Hz packet is sampled once at 10-Hz intervals. A parameter placed four times in a 10-Hz packet is
sampled at 40 Hz.
When multiple packets are defined the acquisition cycle of the chassis is based on the slowest packet out of
the AXN/BCU/40x.
For example:
If two packets are defined, both at 10 Hz, the acquisition cycle is 10 Hz; each parameter in each packet is
sampled at the start of the acquisition cycle and any parameters sampled more than once in any packet are
sampled at even intervals throughout the 10-Hz cycle.
If two packets are defined, one at 1 Hz and one at 10 Hz, the acquisition cycle is 1 Hz with the 10-Hz packet
and its contents are sampled 10 times in the 1-Hz cycle. Each parameter in each packet is sampled at the start
of the acquisition cycle and any parameters sampled more than once in any packet are sampled at even
intervals throughout the 1-Hz cycle.
For packet rates that do not divide evenly into each other, such as 3 Hz or 7 Hz, the acquisition cycle is the
highest common factor of both rates.
6.
To define the contents of a packet, select the package in the Package Properties pane.
7.
Then in the
Placed Data
pane, click the
Place Parameter
button.
Parameters Palette
opens.