WATER BOILER - WB-10 -12

INSTALLATION INSTRUCTIONS

1. Unpack equipment carefully, inspect for any freight damage. Be sure to promptly

put a claim into the freight company if any damage is found.

2. Connect faucet securely to the faucet adapter.

Electrical and plumbing hook-ups should be made by authorized installers only.

INSTALLATION MUST COMPLY WITH ALL NATIONAL AND LOCAL ELECTRICAL AND

PLUMBING CODES.

3. This water boiler can operate on 120, 208 or 220 volt power supply. To ground equip-

ment, connect the ground wire to the green screw on inside bottom of wrap.

4. This boiler comes wired for 208 or 220 volt, single phase, 3 wire plus ground, see wiring

diagram.

5. To connect the water boiler for 120 volt operation:

A. The facility will have two wires, one WHITE (neutral) and the other BLACK. Plus

GREEN for ground.

B. Splice the BLACK wire from power source, to both the heavy RED (#10 AWG) and

thin BLACK (#18 AWG) wires from the WB-10.

C. Take the WHITE wire from the facility power source and splice it to the BLUE wire

(#10 AWG) and WHITE wire (#18 AWG) from the machine (see wiring diagram).

6. Water Hook-Up: Use a 1/4" copper line with a female flare fitting. Water inlet fitting is

located on the back of the WB-10.

CAUTION

Before

 turning thermostat dial to ON position, fill equipment with water up

to the probe tip. This will prevent heating elements from burning out.

1

Summary of Contents for WB-10 -12

Page 1: ...WATER BOILER WB 10 12 6913 West Acco Street Montebello California 90640 Tel 800 421 6150 Technical Support Tel 800 995 0417 Fax 323 837 2401 Revised7 04...

Page 2: ...omes wired for 208 or 220 volt single phase 3 wire plus ground see wiring diagram 5 To connect the water boiler for 120 volt operation A The facility will have two wires one WHITE neutral and the othe...

Page 3: ...PROPER TEMPERATURE POSSIBLE CAUSE SOLUTION PROBLEM WATER WILL NOT REFILL 1 Water line closed or clogged filter 2 Valve coil burned out 3 Grounded probe 4 Defective water level control board TROUBLESH...

Page 4: ...ps at 240 volts 24 amps at 208 volts or 29 amps at 120 volts If you measure only 10 to 12 amps check the current to each element to identify the defective part b Ohmmeter or continuity test Disconnect...

Page 5: ...4 ILLUSTRATED PARTS LIST Water Boiler WB 10 12 B...

Page 6: ...PROBE WATER LEVEL SPACER 1 2 DIA ALUMINUM 8 32 TAP FITTING WATER INLET 1 4 FLARE TUBING ASSEMBLY 1 4 WATER INLET FITTING 1 4 x 3 8 FLARE BRASS ELBOW BUSHING 1 SNAP IN VALVE WATER INLET S 45 THERMOMETE...

Page 7: ...WATT 32 AMP 240 VOLT 8400 WATT 35 AMP L1 NEUTRAL L2 GROUND z 2 3 5 KW HEATING ELEMENTS INLET VALVE Rev 4 15 98 6 z z z z Water Boiler WB 10 12 120 VOLTS 2100 WATTS 17 5 AMPS 1 6 3 1 2 L PROBE ORANGE...

Page 8: ...ng and regular maintenance of this equipment 6 6 6 6 6 Dama Dama Dama Dama Damaged in transit ged in transit ged in transit ged in transit ged in transit Equipment damaged in transit is the responsibi...

Reviews: