TYPE :
Aerosol Generator, Non Thermal, Insecticide, Ultra-Low-Volume (ULV)
ENGINE :
Briggs & Stratton, 4-cycle, single cylinder, gasoline engine, 8 HP,
equipped with electric starter and alternator. The Intek engine feature an advanced
OHV design, offer more power per cubic inch displacement, and provide increased
fuel efficiency. These compact, powerful engines are easy to use and have a long life.
Equipped with a muffler that has a deflector and spark arrester, which is required by
law in some States. Fuel tank of 4 Quarts (3.8 L) capacity. Operating Speed of 2,500
RPM
BLOWER :
Roots - Dresser Universal RAI
R
Positive displacement Blower, straight
lobe, rotary type, direct drive, size 24. Output Air Pressure : Rated at 0 - 7 PSI
Output Air Flow : Rated at 0 - 156 CFM
Exclusive gear box design,
F
igure 8" shape actually improves oil distribution for
longer gear and bearing life with smoother operation.
Taper mounted timing gears, carburized and ground alloy steel gears are precision
machined and taper fitted to alloy steel shaft, eliminating the need for unreliable
timing pins. Original Roots impeller design, dynamically balanced and center-
timed. Long-life anti-friction bearings. All bearing points are engineered for long
service life.
FORMULATION PUMP:
Self-priming positive displacement Diaphragm Pump, Viton
elastomers, dry running capabilities, driven by a 12 VDC permanent magnet motor.
The pump head includes an internal pressure relief valve to allow the pump to
recirculate the liquid so it does not build up excess system pressure to protect the
pump. Adjustable output from 0 to 128 oz./min. (0 - 3840 ml./min).
NOZZLE SYSTEM:
Boom mounted, cluster type with 360
°
horizontal adjustment
(azimuth) . Single nozzle.
2-WAY SOLENOID VALVE ( SHUT-OFF VALVE ):
A corrosion resistant 2-way
solenoid valve is located at the Nozzle Boom assembly and is used for a positive and
instantaneous shut-off of the formulation flow. This is done by placing the SPRAY
switch located on the remote control box into either OFF (Pump stops and 2-way
valve closes) or ON position (Pump runs and 2-way valve opens).
PARTICLE SIZE:
5 - 20 Microns Volume Media Diameter (VMD) depending on flow
rate and viscosity. Bigger droplets can be obtained with higher flow rates and/or lower
boom pressure.
4