REMOTE CONTROL BOX FUNCTIONS
MACHINE SWITCH OFF: R12 V DC system power and grounds gasoline
engine ignition to kill the engine.
MACHINE SWITCH ON: A12 V DC system power and removes ground
from gasoline engine ignition. This position also applies
power to Machine L.E.D. (green light) indicating power is
ON. Be sure to turn
“
OFF
”
after operation of machine, to
prevent discharging battery.
START:
Applies system power to starter solenoid to start the
gasoline engine.
SPRAY ON:
A12V DC on pump motor and 12V DC to spray
switch red light and opens the 2-way solenoid valve on
nozzle boom.
SPRAY OFF:
Removes power to pump motor turning spray switch red
light off and closing the 2-way solenoid valve on nozzle
boom.
REMOTE CONTROL BOX AY.
P/N C-64657