23 Lubricate the inner surface on each
bowl seal with food grade lubricant
(Curtis Part # WC-4916). Install a bowl
seal on the back of each bowl.
24 Set the mixing bowls back in place.
Make sure that the lip on the bottom
of each bowl rests inside the front trim
on the top of the chassis.
continued...
Reassemble the Unit
21 *If removed, install an auger seal on
each drum.
22 Reinstall the augers. Rotate each
auger until it engages completely.
CFBX, CLEANING INSTRUCTIONS
082619J
Daily Cleaning (cont.)
Rinse Out the Drain Tubing
17 Reinstall the drip trays. Position the
drain hose in the opening in the top
of each drip tray. Then, insert the tabs
on the back of the tray into the holes
on the front of the chassis. Push down
gently to secure in place.
18 With the empty drip trays in place,
pour 16 oz./500 ml of warm water
(100-120°F/40-50°C) into the front of
UIFFWBQPSBUPSESJQQBOmSTUPOUIF
left side, then the right side.
19
*GUIFXBUFSEPFTOPUnPXGSFFMZ
insert the brush included with the
unit into the (2) holes in the top of
the evaporator drip pan to clear any
clogs in the tubing that runs down to
the drip trays.
20
"MMPXUIFXBUFSUPmOJTIESBJOJOH
Remove and empty the drip trays.
CLEANING INSTRUCTIONS - CBFX
CI34
NOTICE:
Failure to lubricate
seals may result in leaks.
18
19
20
Left
H
2
0
100°F
Right
Tubing
Brush
17
21
Auger
seal*
22
Auger
Food Grade
Lubricant
23
Bowl
seal
c
d
24