CLEANING INSTRUCTIONS - CBFX
CI34
CFBX, CLEANING INSTRUCTIONS
082619J
Preventive Maintenance - (Perform Every Six Months)
WARNING
• Failure to perform preventive maintenance as required, may result in leaks and/or damage
to the unit. Damage and/or leaks resulting from failure to perform required maintenance is
not covered by the warranty.
•
5IFGPMMPXJOHQSPDFEVSFJTUPCFQFSGPSNFEPOMZCZBRVBMJmFETFSWJDFUFDIOJDJBO
• To avoid personal injury, disconnect the power cord before performing preventive
maintenance.
Empty the Bowls
Skip to step 5 if the bowls are empty.
1 Make sure that the main power
switch is ON.
2 Push the operating mode buttons
repeatedly for each bowl until MIX
appears on the display.
Seal and Bushing Replacement Procedure (All Kits and Parts Sold Separately)
."*/5&/"/$&BQQFBSTPOUIFEJTQMBZFWFSZNPOUITUPSFNJOEZPVUPDBMMBRVBMJmFETFSWJDFUFDIOJDJBOUP
perform seal and bushing replacement. Press any button on the control panel to temporarily clear the display. The
technician will reset the MAINTENANCE reminder during the procedure.
1
Replace every 6 months, or as needed. Use kit # WC-100235 (2 sets per kit).
WC-100216 - Auger seal
Kit # WC-100235
1
Kit # WC-100236
2
WC-100234 - Drum bushing
WC-100010 - Tap seal
WC-100253 - Bowl seal
2
Replace once a year, or as needed. Use kit # WC-100236 (2 sets per kit).
MIX
MIX
40º
F
40º
F
2
1
Also required: Curtis Part # WC-4916, food grade lubricant.
3 Place a large empty container
under each dispenser tap. Drain the
contents out of each bowl. Hold the
container up to the tap to reduce
splashing.
4 Once the bowls are empty, turn OFF
the main power switch.
3
4