background image

Curtis 1620 Manual

page 12

Curtis 1620 Manual

page 11

Programming mode

Description

Programming

Limits

Default Value

Increment

Accuracy*

Definition

BASIC MODE

2

Battery Type

1 or 2

1

1

1

-FLA: Float voltage is set to 26.8V, Constant voltage set to 29V.

2

-SLA: Float voltage set to 27.6V, Constant voltage to 29.4V

End of Charge

1, 2, or 3

1

1

1

-OFF: Charger goes into standby. Charger will cycle to recharge the battery as

determined by 

Vrst

 and enter standby at the end of the charge cycle.

2

-EQUALIZE: Charger adjusts its output current to 

Ito

, and drives the battery to 

Vequ

.

It has the time allotted by 

Tto

 to do this or a fault will occur. An EQUALIZE cycle is  

completed only once. Once the cycle is complete, it changes to the previous setting for
EoC Mode until the next time the EQUALIZE mode is selected.

3

-FLOAT: Charger goes into standby upon entering EoC Mode, and remains in standby

until the battery reaches 

Vfloat

. At this point the charger turns on and maintains 

Vfloat

until power is recycled.

ADVANCED MODE

Constant Current (

Icc)

10-20A

20A

0.5A

+/- 3%

Current used to charge the batteries during normal (bulk charge) operation. This current
is used when the battery voltage is greater than, or equal to 

Vlv

, and less than 

Vcv

.

Constant Voltage Level
(

Vcv)

26-30V

29V

0.1VDC

+/- 1%

Battery voltage maintained by charger during bulk charge. This voltage is maintained by
continuously dropping the output current, until 

Veoc

 is reached.

Low Voltage Current
(

Ilv)

2-10A

6A

0.5A

+/- 5%

Current used to recover deeply discharged batteries; this current is used when the battery
voltage is greater than or equal to 

Vuvlo

, and less than 

Vlv

.

Top-off current

(Ito)

2-10A

6A

0.5A

+/- 5%

Current used to Equalize the batteries.

End of charge ("soft" overvoltage)
(

Veoc)

29-35V

31VDC

0.1V

+/- 1%

Charger goes into "soft" overvoltage mode, from which it recovers when battery voltage
drops below 

Vrst

.

EoC Threshold (

Icv)

2-20A

4A

0.5A

+/- 3%

Current at which the charger transitions to EoC mode.

Restart Voltage  (

Vrst)

22-28v

26VDC

0.1V

+/- 1%

Used when EoC Mode is EQUALIZE or OFF; the battery voltage at which charger
automatically turns on and recharges the battery. Charger must be in stand by mode when
this voltage is detected; the charger will charge the battery until it reaches 

Vcv

 and then

enter stand by mode.

Bulk Charge Threshold

 

(

Vlv)

0-26VDC

24VDC

0.1VDC

+/- 1%

Battery voltage at which the charger switches from 

Ilv

 to 

Icc

.

Low Voltage Lockout
(

Vuvlo)

4-21VDC

5VDC

0.1VDC

+/- 1%

Battery voltage below which the charger will not turn on.

Equalize Voltage  (

Vequ)

29-33V

31VDC

0.1VDC

+/- 1%

Used when EoC Mode is EQUALIZE. The voltage at which the EQUALIZE mode is
ended, unless the mode ends by reaching 

Tto

.

Float Voltage  (

Vfloat)

25-30V

26.8V

0.1VDC

+/- 1%

Used when EoC Mode is FLOAT. Once the battery voltage drops to this set point, the
charger will turn on and stay on, maintaining this battery voltage.

Low Voltage Timeout  (

Tlv)

1-10hrs

1 hour

1 hour

+/- 5min

If battery does not reach 

Vlv

 within this timeout period, an error is indicated.

Equalize Timeout (

Tto)

0-5hrs

2 hours

1 hour

+/- 5min

Used when EoC Mode is EQUALIZE. Number of  hours charger is kept at equalization
current, unless the mode is ended by reaching 

Vequ

.

Maximum Charge Time
(

Tcmax)

2-36hrs

16 hours

1 hour

+/- 1hr

The maximum amount of time the charger has to complete a charge cycle and enter
standby mode. Failure to complete charge in the allotted time will result in a fault mode.

1 Accuracy is calculated as percentage of the maximum setting.
2 Items in bold are as they appear in the display of the 1311 handheld programmer.

Table 1. Programming Parameters

Summary of Contents for 1620

Page 1: ...registered trademark of Curtis Instruments Inc M MA AN NU UA AL L MODEL 1620 S W I T C H M O D E BATTERY CHARGER Before charging read instructions carefully Applicable to 230VAC units only CURTIS INSTRUMENTS INC 200 Kisco Avenue Mt Kisco NY 10549 Tel 914 666 2971 FAX 914 666 2188 www curtisinst com ...

Page 2: ... 32V and a maximum of 30A between the battery and the charger 10 CAUTION It is recommended that you disconnect the AC power cord before connecting or disconnecting the charger to the battery 11 CAUTION Not intended for outdoor use 12 CAUTION Charger surface may be hot while plugged in and for a period of time thereafter 13 CAUTION Units with fans must have at least 30mm of clearance on the vented ...

Page 3: ... programmer only Pin Function 1 Rx 2 SEC_RTN 3 Tx 4 12V Motor Controller Inhibit Molex 39 01 4030 Capable of sinking up to 60mA DC to ground Pin Function 1 See wiring diagram 2 No connection 3 See wiring diagram DC Power Output 2 x M5 studs Pin Function B output B output Curtis 1620 Manual page 1 1 2 1620uv www xx yy zzz 1620 u v www xx yy zzz Model Cooling Sealing Input Output Output Series Volta...

Page 4: ...possibilities occur charging will stop and the 1620 will set itself to Off Mode the charger remains in standby until restart voltage Vrst is reached Curtis 1620 Manual page 4 2 7 1 End of Charge Mode Figure 1 Charge profile for End of Charge Mode Figure 1 defines the charge profile for the End of Charge Mode As long as the battery voltage V is above Undervoltage Lockout Level Vuvlo charging will s...

Page 5: ...nter standby mode The charger will continue this cycle of standby reactivation until power is removed or until the Model 1311 programmer is connected Curtis 1620 Manual page 5 2 7 4 Equalize Mode after Float Mode Figure 4 Charge profile for Equalize Mode after Float Mode Only flooded lead acid FLA batteries require equalization In order to prevent dam age to the battery the charger will go through...

Page 6: ...he programmer to the 4 pin Molex connector between the indicators The yellow and green indicators will blink on and off simultaneously indicating that the charger is in programming mode 4 3 2 Configure the programmable parameters defined in Section 4 2 4 3 3 Once the programmable parameters have been defined disconnect the 1311 programmer from the charger The charger will reset and resume normal o...

Page 7: ...y be damaged or old Replace battery Yellow blinks 2 twice Not reaching Vlv Battery manufacturer s rated capacity may 2 seconds off repeats within Tlv exceed charger s rating Increase Tlv decrease Green off Vlv increase Ilv or reset the charger 3 Battery may be damaged or old Replace battery No indicators on No power or Charger may be unplugged Check for damaged charger AC power Charger may be dama...

Page 8: ...qualize the batteries End of charge soft overvoltage Veoc 29 35V 31VDC 0 1V 1 Charger goes into soft overvoltage mode from which it recovers when battery voltage drops below Vrst EoC Threshold Icv 2 20A 4A 0 5A 3 Current at which the charger transitions to EoC mode Restart Voltage Vrst 22 28v 26VDC 0 1V 1 Used when EoC Mode is EQUALIZE or OFF the battery voltage at which charger automatically turn...

Reviews: