INSTALLATION
8
Reversing the Door Swing
Tools required: Philips style screwdriver / Flat bladed screwdriver / Hexagonal spanner
• Ensure the unit is unplugged and empty.
• To take the door off it is necessary to tilt the unit backwards. You should rest the unit on
something solid, e.g. a chair just below the top panel.
• All parts removed must be saved to do the reinstallation of the door.
• Do not lay the unit flat as this may damage the coolant system.
• We recommend that 2 people handle the unit during assembly.
• If you want to have the door swing reversed, we recommend that you contact a qualified
technician. You should only try to reverse the door yourself if you believe that you are
qualified to do so.
1. Remove the upper hinge cap (1).
2. Remove the two upper screws and hinge bracket (2) from the unit top.
3. Carefully lift the door up and remove it from the unit. Place door on a padded surface to
prevent from scratching.
4. Remove the plug (3) and shaft sleeve (6) from the door and reattach them to the
corresponding position on the opposite side of the door. Press the plug firmly into the
hole.
5. Remove the two lower screws, hinge bracket and levelling leg (4) from the unit bottom.
6. Remove the screw-type levelling front leg (5) from unit bottom and transfer it to the
corresponding position on the opposite side of the unit bottom.
7. Reattach the two lower screws, hinge bracket and levelling front leg (4) to the opposite
side of the unit bottom. Loosely secure.
8. Carefully set the door back into place, sliding it onto the bottom hinge.
9. Securely reattach the two upper screws and hinge bracket (2) to the unit top on the
opposite the side from which it was removed. Ensure that the hinge pin is properly
positioned in the bushing (hole) at the top of unit door.
10. Reattach the hinge cap (1) over the top hinge bracket.
Summary of Contents for CUF50W12
Page 1: ...INSTRUCTION MANUAL 50CM UNDERCOUNTER FREEZER CUF50W12 ...
Page 2: ......