3a. Tether Attachment
• Verify service leads meet nameplate temperature rating.
• Install tether (if required) with #10 screws included in
fixture package to hole on back of the housing as
shown in figure 5. The other end of tether is connected
to center threaded stud on backplate using hex nut
provided (Figure 6).
3b. Service Leads
• Route service leads through conduit & hub to the
fixture junction box as in figures 7 and 8.
• Units are provided with leads exiting the fixture for
connection with service leads and (if ordered) wired
dimming.
• Connect power to luminaire where Black is Line, White
is Neutral and Green is Ground.
3c. Wired Dimming
• Connect wired dimming leads per Table 1
• Customer supplied dimming leads 600 volt min.
TABLE 1. Wired Dimming Control Connections
0 VDC (-)
Gray Lead
Up to 10 VDC (+)
Violet Lead
3d. Install fixture to backplate
on the backplate and the provided hex nuts as shown
• Tighten hex nuts to 30 in-lbs.
• Occasional cleaning of the outer lens surface may be
needed.
• Use a mild, non-abrasive soap or detergent, of neutral
pH (pH approximately 6 to 8), containing no chlorinated
or aromatic hydrocarbons.
• Wash thoroughly, using a soft cloth.
• Rinse with clean, cold water and wipe dry.
RISK OF ELECTRICAL SHOCK. Make certain power is off
before attempting any maintenance of the product.
WARNING
Installation Guide
Evolve
®
Petro Canopy Light (ECLP)
3
NOTE: Make all electrical connections in accordance with
the National Electrical Code and any applicable local code
requirements including grounding.
NOTE: Verify supply voltage matches rating before wiring.
Wiring & Mounting Fixture
3
Maintenance/Cleaning
4
Figure 6
Figure 7
Figure 8