M1277-0
ENGLISH
12
limeters to the connector on the tank and run it through the
hole (F).
• Put the tank with the drain tube back in its place.
• Then close the front door.
E
ATTENTION: to guarantee regular drainage of the
water, make sure that the drainpipe has a slope and
is straight, without any bends or constrictions. In any
case the floating device inside the tank is active and
will stop the dehumidifier when full.
m
aintenance
The dehumidifiers of the DL series need no particular mainte-
nance. It is advisable to dust them and keep the air intake and
outlet grids clean. Contact your dealer if it should function badly
or break down.
B
This appliance contains flammable pressurized refrig-
erant: any maintenance concerning the refrigerant
circuit must be carried out by technical personnel who
have a valid certificate issued by an accredited orga-
nization, which certifies their competence to operate
safely with this type of refrigerants.
The power supply cable has an M type connection; in the event
of damages the cable must be replaced with a similar one only by
experienced and qualified staff.
B
Maintenance on the electrical or mechanical parts
must be carried out taking into account the flam-
mable refrigerant fluid. Before intervening, make
sure you have eliminated all possible ignition sources,
check that the capacitors are discharged, that there
are no live parts, that the appliance is properly con-
nected to earth.
The refrigerant fluid is odorless: if you suspect that there is a
refrigerant gas leak, properly ventilate the room before doing
anything else.
E
ATTENTION: Before doing anything on the appli-
ance disconnect the power supply by unplugging the
machine.
h
ow
to
Clean
the
Filter
The filter can be cleaned with a vacuum cleaner or with water: in
this case dry it before assembly.
C
Keep the air filter clean, especially in dusty rooms: a
dirty filter reduces the air flow and efficiency of the
dehumidifier.
h
ow
to
remove
the
air
Filter
Open the front door: the air filter simply stands on the front
grid.
Pic.7 –
How to place the air filter on the front grid.
h
ow
to
put
the
air
Filter
on
Place the air filter on the stainless steal support and put the up-
per side on the central flap (L) of the rear grid (Pic.7): then close
the front panel.
s
torage
• Keep the appliance in a room with a temperature between
–25°C and +55°C.
• When the appliance is still packed follow the instructions on
the box.
• Do not place other heavy material on the box.
c
hecks
to
carry
out
before
and
after
a
Long
period
of
inactivity
b
eFore
• Disconnect the plug and empty the condensate collection
tank;
• Cover the machine to protect it from dust.
a
Fter
• The fan must turn freely without gripping;
• Start the machine following this manual’s instructions.