6.3. Product
disposal
The machine is mainly composed of plastic components, and some metal parts, both recyclable. Before
disposing of it, separate the plastic parts (body, cover, grille, etc.) from the metal ones (motor bracket, wall
installation bracket, etc.). Remove the electrical cabling and dispose of it as by standard regulations
7. Problems and solutions
7.1. The humidifier doesn’t start
POSSIBILE CAUSES
SOLUTIONS
The power supply is interrupted
Check the electrical connections, starting from the
electrical control box to the internal box of the humidifier
The start capacitor is burned
Substitute the capacitor with a new one
7.2. Air comes out from the air outlet but not nebulized water
POSSIBILE CAUSES
SOLUTIONS
Water does not arrive to the basin
Check that the water supply tap is opened.
Check that the water feed solenoid valve filter is not
obstructed, and that the hoses are correctly fitted and
unobstructed. Finally, check that the floating switch
inside the basin is free to move correctly.
The fan cone extremity is obstructed
Clean the cone from the impurities and dirt inside
7.3. The Humidifier continuously discharging water
POSSIBILE CAUSES
SOLUTIONS
The siphon is dirty
When dirt accumulates inside the siphon, it is possible
that the siphon is triggered during normal operation.
Disassemble and clean the siphon completely (see: par.
5.3 Inspection and Cleaning of the Discharge Siphon)
The machine is installed not vertically
Check that the machine is installed as described on
par.3.2 Positioning.