background image

4801-1020

 Super-Saver XL

TM

 Heater

31

10. Warranty

Limited Warranty - Protein Products

The GSI Group, LLC. (“GSI”) warrants products which it manufactures, to be free of defects in materials and workmanship 
under normal usage and conditions for a period of 12 months from the date of purchase (or, if shipped by vessel, 14 months 
from the date of arrival at the port of discharge). If, in GSI’s sole judgment, a product is found to have a defect in materials 
and/or workmanship, GSI will, at its own option and expense, repair or replace the product or refund the purchase price. 
This Limited Warranty is subject to extension and other terms as set forth below.

Warranty Enhancements:

The warranty period for the following products is enhanced as shown below and is in lieu of (and not in addition to) the 
above stated warranty period.

Conditions and Limitations:

THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH 
HEREIN; SPECIFICALLY, GSI DISCLAIMS ANY AND ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR 
IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE OR USE IN CONNECTION WITH: (I) ANY PRODUCT MANUFACTURED OR SOLD BY 
GSI, OR (II) ANY ADVICE, INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT, 
REPRESENTATIVE OR EMPLOYEE OF GSI REGARDING OR RELATED TO THE CONFIGURATION, INSTALLATION, 
LAYOUT, SUITABILITY FOR A PARTICULAR PURPOSE, OR DESIGN OF SUCH PRODUCTS.

The sole and exclusive remedy for any claimant is set forth in this Limited Warranty and shall not exceed the amount paid 
for the product purchased. This Warranty only covers the value of the warranted parts and equipment, and does not cover 
labor charges for removing or installing defective parts, shipping charges with respect to such parts, any applicable sales 
or other taxes, or any other charges or expenses not specified in this Warranty. GSI shall not be liable for any other direct, 
indirect, incidental or consequential damages, including, without limitation, loss of anticipated profits or benefits. Expenses 
incurred by or on behalf of a claimant without prior written authorization from the GSI warranty department shall not be 
reimbursed. This warranty is not transferable and applies only to the original end user. GSI shall have no obligation 
or responsibility for any representations or warranties made by or on behalf of any dealer, agent or distributor. Prior to 
installation, the end user bears all responsibility to comply with federal, state and local codes which apply to the location 
and installation of the products.

This Limited Warranty extends solely to products sold by GSI and does not cover any parts, components or materials used 
in conjunction with the product, that are not sold by GSI. GSI assumes no responsibility for claims resulting from 
construction defects, unauthorized modifications, corrosion or other cosmetic issues caused by storage, application or 
environmental conditions. Modifications to products not specifically delineated in the manual accompanying the product at 
initial sale will void all warranties. This Limited Warranty shall not extend to products or parts which have been damaged 
by negligent use, misuse, alteration, accident or which have been improperly/inadequately maintained.

Service Parts:

GSI warrants, subject to all other conditions described in this Warranty, Service Parts which it manufactures for a period 
of 12 months from the date of purchase, unless specified in Enhancements above. Parts not manufactured by GSI will carry 
the Manufacturer’s Warranty.

Product

Warranty Period

AP

®

 Fans

Performer Series Direct Drive Fan Motor

3 Years

* Warranty prorated from material list price:

0 to 3 years - no material cost to end user
3 to 5 years - end user pays 25%

5 to 7 years - end user pays 50%

7 to 10 years - end user pays 75%

** Warranty prorated from material list price:

0 to 3 years - no material cost to end user
3 to 5 years - end user pays 75%

AP

®

 and Cumberland

®

Flex-Flo/Pan Feeding System Motors

2 Years

Electronic Controls

All Protein controls manufactured by GSI

24 Months from date
code on part

Cumberland

®

Feeding and Watering
Systems

Feeder System Pan Assemblies

5 Years, Prorated **

Feed Tubes (1.75" and 2.00")

10 Years, Prorated **

Centerless Augers

10 Years, Prorated **

Watering Nipples

10 Years, Prorated **

(Protein Limited Warranty_REV01_06 November 2018)

Summary of Contents for Super-Saver XL HH-SS-120-XL

Page 1: ...4801 1020 Super Saver XLTM Heater Agricultural Building Heater 120V 60 Hz ETL Owner s Manual 4801 1020 Version 4 0 Date 05 08 19...

Page 2: ...os and specifications in this manual are based on the latest information available at the time of publication The right is reserved to make changes at any time without notice Standing Pilot Ignition W...

Page 3: ...4 Installing the Dual Flare Duct 14 Connecting the Gas Supply 14 Chapter 4 User Instructions 15 Connecting Electrical Power 15 Start Up 15 Shutting OFF Heater 16 Variable Heat Output Adjustment 17 Cha...

Page 4: ...y out of the work area at all times Alterations must not be made to the equipment Alterations can produce dangerous situations resulting in SERIOUS INJURY or DEATH This equipment must be installed in...

Page 5: ...is symbol indicates an imminently hazardous situation which if not avoided will result in serious injury or death This symbol indicates a potentially hazardous situation which if not avoided can resul...

Page 6: ...ly a fire or explosion can result causing property damage personal injury or loss of life Carefully read all safety messages in this manual and safety signs on your machine Keep signs in good conditio...

Page 7: ...each use and at least annually by a qualified service person Be aware that the heater may operate under automatic control and may start without warning Do not service the heater without first disconne...

Page 8: ...n result in electric shock personal injury or death If permanently connected to power supply make sure a circuit breaker or similar cutoff device is provided to permit disconnection of power for servi...

Page 9: ...The equipment shall be installed in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Check all connections for gas leaks Do not operate heater with door open or panels Do not move or ha...

Page 10: ...e the heater in spaces which contain or may contain volatile or airborne combustibles or products such as gasoline solvents paint thinner dust particles or unknown chemicals Failure to follow these in...

Page 11: ...n Off Sheet Below is a sign off sheet that can be used to verify that all personnel have read and understood the safety instructions This sign off sheet is provided for your convenience and personal r...

Page 12: ...it is operating hot or connected to power supply 8 Turn power OFF before servicing Heater may start at any time if power is connected 9 Heater is not recommended for heating human living quarters 10 N...

Page 13: ...ge 14 Specifications and Requirements NOTE Refer to heater ratings plate for unit voltage amperage and frequency ratings Models 250K BTU Universal Mount Weight 153 lbs Height 32 81 cm Width 27 1 2 70...

Page 14: ...a carpenter s level to check that the heater is level Installing the Dual Flare Duct Fold Dual Flare duct 1 to shape as shown in Figure 3A Install Dual Flare duct to heater exhaust as shown with sheet...

Page 15: ...ore turning ON gas verify that the main supply valve is open Check all connections for leaks with a soap and water gas leak testing solution Verify the gas valve knob is in the ON position If not turn...

Page 16: ...Danger label listed under Acceptable Pressures on the outside of the heater This should be done only by a qualified gas installer Operating the heater at a pressure too high or too low will adversely...

Page 17: ...valve 1 can be adjusted to deliver either minimum heat or maximum heat When the throttle valve handle is parallel to the gas flow the valve is completely open to deliver maximum heat output Refer to...

Page 18: ...for gas leaks with an approved gas leak testing solution applying a soapy water mixture to gas connections works well Bubble formation indicates a leak 6 Keep heater clean at all times a Open doors a...

Page 19: ...4801 1020 Super Saver XLTM Heater 19 6 Wiring Diagrams SPI Model Component and Wiring Diagram...

Page 20: ...6 Wiring Diagrams SPI Model 20 4801 1020 Super Saver XLTM Heater Ladder Type Schematic Diagram...

Page 21: ...time required to troubleshoot this system 1 Turn OFF the gas supply at the main gas valve 2 Disconnect electric power to the system at the main fuse of the circuit breaker if connected 3 Visually ins...

Page 22: ...ngth from meter to most remote heater length from a to e or g 100 30 m 25 8 m 125 38 m Minor loss equivalents from Table 1 1 gate valve x 2 valve 1 m valve 3 tees x 11 tee 4 m tee 35 13 m Calculated E...

Page 23: ...Gate valve 4 Gas Meter Minor Loss Equivalents Fitting 2 5 08 cm IPS or Smaller 2 5 08 cm IPS to 4 10 16 cm IPS Feet per Fitting Meters per Fitting Feet per Fitting Meters per Fitting 45 Elbow 3 1 5 2...

Page 24: ...0 1 1 4 1 380 1400 950 770 660 580 530 490 460 430 400 325 280 219 206 1 1 2 1 610 2100 1460 1180 990 900 810 750 690 650 620 500 430 325 309 2 2 067 3950 2750 2200 1900 1680 1520 1400 1300 1220 1150...

Page 25: ...eplacement parts When ordering service parts please specify the country model number date of manufacture voltage frequency gas type inside or outside mount and whether the heater is constructed of gal...

Page 26: ...9 Parts List 26 4801 1020 Super Saver XLTM Heater 250K BTU SPI Continued NOTE The parts pointed out on this page are listed on Page 30...

Page 27: ...9 Parts List 4801 1020 Super Saver XLTM Heater 27 250K BTU SPI Continued NOTE The parts pointed out on this page are listed on Page 30...

Page 28: ...9 Parts List 28 4801 1020 Super Saver XLTM Heater 250K BTU SPI Continued NOTE The parts pointed out on this page are listed on Page 30...

Page 29: ...9 Parts List 4801 1020 Super Saver XLTM Heater 29 250K BTU SPI Continued NOTE The parts pointed out on this page are listed on Page 30...

Page 30: ...ot Lite 1 1 4 x 2 22 3004 0120 S Gas Valve HW Pilot LP with Silicone Added 3004 0121 S Gas Valve HW Pilot NG with Silicone Added 23 2000 0001 HH Tubing ASTM B280 Formed 23 5 16 24 1009 1500 Valve Bron...

Page 31: ...n behalf of a claimant without prior written authorization from the GSI warranty department shall not be reimbursed This warranty is not transferable and applies only to the original end user GSI shal...

Page 32: ...des and applicable regulations which should be carefully followed in all cases Authorities having jurisdiction should be consulted before installations are made 1004 E Illinois St Assumption IL 62510...

Reviews: