Cycle Plus Pan Feeder Control Installation (Continued)
Programming
All programming is done with the program keys--modify, increase (up arrow), decrease (down arrow), and
enter. The only program information that will be lost if power is out for an extended period of time is Time
of Day. All other program information will be retained even during extended power loss. With all program
functions, if the increase or decrease switches are depressed and held down, the count will increase or
decrease at the rate of approximately four counts per second.
Time of Day:
Select time of day function by depressing the Time of Day switch, then depress the Program
switch. The hour digits to the left of the colon will begin flashing. Increase the hour with the increase switch
and decrease the hour with the decrease switch. The AM/PM indicator on the right hand part of the display
indicates if the hour is AM or PM. Day 1 and Day 2 indicator indicate which day is set. After the hour is
correctly entered, depress the Enter switch. The hour digits stop flashing and the minutes digits to the right
of the colon begin flashing. Increase or decrease the minutes with the increase/decrease switches. After
the minute has been correctly entered, depress the Enter switch. The new time is entered, seconds are
set to 0 and the new time begins at the moment the Enter switch is depressed.
The time set mode may be exited anytime by depressing any switch other than the four (4) programming
switches. Exiting the program mode by depressing a non-programming switch will cause the new hour or
minute not to be entered. In order to set a new time, the Enter switch must be depressed. Example: Enter
time set mode with = 10:00 AM. Using the increase switch, set the time to 11:00 AM. Then depress a
non-program switch (including Time of Day switch). The new time will remain 10:00 AM.
Feedings per Day:
Select the Feedings per Day function. Then depress the modify switch to enter the
Feedings per Day program mode. By using the increase/decrease switches, you may enter any number
of feedings from 0 through 20. Zero feedings per day will prohibit all feedings. To enter the new value you
must depress the Enter switch. As with the time set mode, you may exit the Feedings per Day mode,
leaving the old Feedings per Day value undisturbed, by depressing any non-program switch.
Feeding Start Time:
The start time for each feeding, one through 20, must be individually programmed.
When the Feeding Start Time mode is entered, the display will alternate between the feeding number and
the time of that feeding. To enter a new start time for a particular feeding, enter the Feeding Start Time
mode by depressing that switch. Then, using the increase/decrease switches increment or decrement the
feeding number until the feeding number whose time you wish to alter is on the display. Then depress the
Modify switch to alter the time of that feeding. Depress the Enter switch to enter the new time.
Feeding Run Time:
The run time for each feeding one through 20 must be individually programmed.
When the Feeding Run Time mode is entered, the display will alternate between the feeding number and
the run time of that feeding. To enter a new run time for a particular feeding, enter the Feeding Run Time
mode by depressing that switch. Then, using the increase/decrease switches, increment or decrement the
feeding number until the feeding number whose run time you wish to alter is on the display. Then depress
the Modify switch to alter the run time of that feeding. Enter the time you wish the feeder to run in minutes
(left two (2) digits) and seconds (right two (2) digits). The maximum run time is 99 minutes and 59 seconds.
Depress the Enter switch to enter the new run time value. Zero run time will prohibit all feedings.
Fill System Delay:
The Fill System Delay is the length of time in minutes and seconds that the feeder fill
system will start before the first feeding. To enter a new fill system delay enter the Fill System Delay mode
by depressing that switch and depress the Modify switch to alter the fill system delay. Enter the time you
wish the delay to be run in minutes (left two (2) digits) and seconds (right two (2) digits). The maximum
delay time is 30 minutes and 59 seconds. Depress the Enter switch to enter the new delay time value.
Zero run time will prohibit all feedings.
Summary of Contents for PNEG-499
Page 1: ...PNEG 499 Cycle Plus Pan Feeder Installation and Operation Manual PNEG 499 Date 01 01 15...
Page 2: ...2 PNEG 499 Cycle Plus Pan Feeder...
Page 48: ...48 PNEG 499 Cycle Plus Pan Feeder NOTES...
Page 52: ...52 PNEG 499 Cycle Plus Pan Feeder NOTES...
Page 53: ...7 Parts List PNEG 499 Cycle Plus Pan Feeder 53 Grilled Centerhouse Control Unit Components...