Cumberland
1004 E. Illinois St.
Assumption,IL 62510
PHONE 1-217-226-4421
FAX 1-217-226-4420
Manual Part No. 4801-5323 Rev 1-2015 Page
6
of
12
MEGA
-FLOW CON FAN
Fan & Cone Installation
Figure 4:
Install Belt
Belt
Tensioner
Straight
Edge
Fan Pulley
3.
Align the Pulleys using a straight edge as shown
in
Figure 4
. After the pulleys are aligned, install
Cog Belt onto motor pulley, tension pulley, and
prop pulley. Recommended torque of the lock
screws on the Bearing Pillows are 65 in.-lbs.
min, and 83 in.-lbs. max. After aligning the
pulley, tighten the Motor Pulley.
4.
Apply power to fan at this point to check
motor/prop for proper operation
. WARNING:
Incorrect motor rotation can damage fan
internals and possibly cause injury!
Remove
all electrical power after testing motor before
proceeding with Fan installation.
5. Assemble Cone
54” Cone
52” Cone
36” Cone
Description
Quantity
0404-10603
0404-8253
0404-10048
Cone Sections
4
1004-1424
1004-1424
1004-1424
3/8"-16 x 1-
1/4” Cap Screws
4
1001-1457
1001-1457
1001-1457
3/8"-16 Nuts
4
1003-6027
1003-6027
1003-6027
3/8" Washers
8
6403-3050
6403-0147
6403-0135
PVC Coated Cone Guard
1
1001-1446
1001-1446
1001-1446
¼" x20 Nuts
4
1004-9045
1004-9045
1004-9045
#14 x ½ Screws
8
1004-6013
1004-6013
1004-6013
¼"-20 x 3/4" Truss Head Scr
4
0404-10652
0404-8252
0404-10291
Cone Bracket
4
Tools Required
Cordless drill
Ratchet
7/16 in. (11 mm) Wrench
9/16 in. (14 mm) Wrench
Marker or Scribe
9/16 in. (14 mm) Socket
3/8”, 5/16”, 7/16” Nut
Driver
½”socket
7/16 in. (11 mm) Socket