background image

 

Cumberland

  

 1004 E. Illinois St.  

 Assumption,IL 62510  

 PHONE 1-217-226-4421  

 FAX 1-217-226-4420 

Manual Part No. 4801-5323 Rev 1-2015                                                          Page 

6

 of 

12 

 

MEGA

-FLOW CON FAN 

Fan & Cone Installation

 

Figure 4: 

Install Belt 

Belt 
Tensioner 

Straight 
Edge 

Fan Pulley 

 

3. 

Align the Pulleys using a straight edge as shown 
in 

Figure 4

.   After the pulleys are aligned, install 

Cog Belt onto motor pulley, tension pulley, and 
prop pulley.  Recommended torque of the lock 
screws on the Bearing Pillows are 65 in.-lbs. 
min, and 83 in.-lbs. max.  After aligning the 
pulley, tighten the Motor Pulley. 

 

 

4. 

Apply power to fan at this point to check 
motor/prop for proper operation

. WARNING: 

Incorrect motor rotation can damage fan 
internals and possibly cause injury!  

Remove 

all electrical power after testing motor before 
proceeding with Fan installation.

 

 

 

 

 

 

 

5. Assemble Cone 

  

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

54” Cone 

52” Cone 

36” Cone 

Description 

Quantity  

0404-10603 

0404-8253 

0404-10048 

Cone Sections 

1004-1424 

1004-1424 

1004-1424 

3/8"-16 x 1-

1/4” Cap Screws 

1001-1457 

1001-1457 

1001-1457 

3/8"-16 Nuts 

1003-6027 

1003-6027 

1003-6027 

3/8" Washers 

6403-3050 

6403-0147 

6403-0135 

PVC Coated Cone Guard  

1001-1446 

1001-1446 

1001-1446 

 ¼" x20 Nuts 

1004-9045 

1004-9045 

1004-9045 

#14 x ½ Screws 

1004-6013 

1004-6013 

1004-6013 

¼"-20 x 3/4" Truss Head Scr 

0404-10652 

0404-8252 

0404-10291 

Cone Bracket 

 

Tools Required

 

Cordless drill 

Ratchet 

7/16 in. (11 mm) Wrench 

9/16 in. (14 mm) Wrench 

Marker or Scribe 

9/16 in. (14 mm) Socket 

3/8”, 5/16”, 7/16” Nut 

Driver 

½”socket 

7/16 in. (11 mm) Socket 

 

Summary of Contents for MEGA-FLOW CONE FAN Series

Page 1: ...ure maximum fan life Remove dirt with a dry brush or compressed air DO NOT SPRAY MOTOR WITH WATER OR CLEANING FLUIDS 3 Fan performance may be greatly reduced by damaged or dirty shutter Clean and insp...

Page 2: ...Part No 4801 5323 Rev 1 2015 Page 2 of 12 MEGA FLOW CON FAN Fan Cone Installation 1 Table of Contents Section Description Page 1 Table of Contents 2 2 Warranty 3 3 Framing Instructions 4 4 Fan Mounti...

Page 3: ...ts incurred in the performance of this extended warranty Conditions and Limitations THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH ABOVE SPECIFICALLY GSI MAKES N...

Page 4: ...lectric or cordless drill 3 8 10 mm Socket 12pt star Thread Locking Compound LOCKTITE 1 2 13 mm socket Figure 2 Fan Spacing with Cone Fan Housing Cone Center to Center Spacing Fan Size Spacing Spacing...

Page 5: ...e Figure 3 NOTE Ensure the fan is raised to the top of the rough opening before housing is attached to the wall The top three screws should be attached first 2 Securely attach fan to wall with screws...

Page 6: ...Incorrect motor rotation can damage fan internals and possibly cause injury Remove all electrical power after testing motor before proceeding with Fan installation 5 Assemble Cone 54 Cone 52 Cone 36 C...

Page 7: ...ed on the outside of the cone assembly Do not tighten nuts Refer to Figures 6 8 d Once four 4 cone panels are assembled stand assembly up on large radius side Refer to Figure 5 e Pull both ends togeth...

Page 8: ...s in each mounting bracket NOTE Make sure bottom panel with drain hole is closest to the ground b Bend the mounting brackets back slightly to help clear the area of the cone edges Mount cone to fan Ha...

Page 9: ...bolts from the inside of the cone through the mounting brackets See Figure 10 d Tighten 1 4 20 cone assembly nuts and bolts e For 36 52 and 54 Fans Install the Outside Fan Guard using four 3 8x1 1 4 b...

Page 10: ...place manually open vanes of shutter to access latch Fasten latch located inside fan housing into slot in flange of shutter Firmly lock down latch Repeat procedure to latch opposite side of shutter 8...

Page 11: ...Cumberland 1004 E Illinois St Assumption IL 62510 PHONE 1 217 226 4421 FAX 1 217 226 4420 Manual Part No 4801 5323 Rev 1 2015 Page 11 of 12 MEGA FLOW CON FAN Fan Cone Installation...

Page 12: ...Illinois St Assumption IL 62510 PHONE 1 217 226 4421 FAX 1 217 226 4420 Manual Part No 4801 5323 Rev 1 2015 Page 12 of 12 MEGA FLOW CON FAN Fan Cone Installation Copyright 2015 by The GSI Group LLC P...

Reviews: