-FLOW CONE FAN 

Fan & Cone Installation

 

When this fan is used in a life support ventilation 

system where failure could result in loss or injury, 

the user should provide adequate backup 

ventilation, or accept the risk of such loss or injury. 

IMPORTANT! 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BEFORE INSTALLING 

1.  Inspect fan for damage in transit.  Check for 

loose, missing, or damaged parts. 

2.  If there are any missing parts or if there is 

any shipping damage, do not attempt to 
operate fan.  Contact your Distributor. 

 

MAINTENANCE 

1.  Read WARNING statements before proceeding. 
2.  Blades, motor, and wire guards should be 

cleaned periodically to decrease vibration and 
ensure maximum fan life.  Remove dirt with a 
dry brush or compressed air.  DO NOT SPRAY 
MOTOR WITH WATER OR CLEANING FLUIDS. 

3.  Fan performance may be greatly reduced by 

damaged or dirty shutter.  Clean and inspect 
shutter periodically to ensure maximum fan 
performance. 

1.  Fan should be securely mounted to wall.  Refer 

to mounting instructions on Section 4 of this 
manual. 

2.  The cone and wire guard must always be 

installed for your protection. 

National safety codes require that guards be 
installed if within 7 feet (2.1 m) of floor or within 
reach of personnel or livestock. 

3.  If thermostat is used, connect fan power cord to 

controller. 

INSTALLATION 

1.  Disconnect power source before installing or 

servicing fan.  Failure to disconnect power 
source can result in property damage, 
serious injury, or death. 

2.  When connected to an automatic controller, 

FAN MAY START AT ANY TIME. 

3.  IMPORTANT!  Before Operating Fan, Inspect 

Fan For any Object That May Obstruct Blade 
Rotation. 

WARNING! 

Summary of Contents for MEGA-FLOW CONE FAN Series

Page 1: ...ure maximum fan life Remove dirt with a dry brush or compressed air DO NOT SPRAY MOTOR WITH WATER OR CLEANING FLUIDS 3 Fan performance may be greatly reduced by damaged or dirty shutter Clean and insp...

Page 2: ...Part No 4801 5323 Rev 1 2015 Page 2 of 12 MEGA FLOW CON FAN Fan Cone Installation 1 Table of Contents Section Description Page 1 Table of Contents 2 2 Warranty 3 3 Framing Instructions 4 4 Fan Mounti...

Page 3: ...ts incurred in the performance of this extended warranty Conditions and Limitations THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH ABOVE SPECIFICALLY GSI MAKES N...

Page 4: ...lectric or cordless drill 3 8 10 mm Socket 12pt star Thread Locking Compound LOCKTITE 1 2 13 mm socket Figure 2 Fan Spacing with Cone Fan Housing Cone Center to Center Spacing Fan Size Spacing Spacing...

Page 5: ...e Figure 3 NOTE Ensure the fan is raised to the top of the rough opening before housing is attached to the wall The top three screws should be attached first 2 Securely attach fan to wall with screws...

Page 6: ...Incorrect motor rotation can damage fan internals and possibly cause injury Remove all electrical power after testing motor before proceeding with Fan installation 5 Assemble Cone 54 Cone 52 Cone 36 C...

Page 7: ...ed on the outside of the cone assembly Do not tighten nuts Refer to Figures 6 8 d Once four 4 cone panels are assembled stand assembly up on large radius side Refer to Figure 5 e Pull both ends togeth...

Page 8: ...s in each mounting bracket NOTE Make sure bottom panel with drain hole is closest to the ground b Bend the mounting brackets back slightly to help clear the area of the cone edges Mount cone to fan Ha...

Page 9: ...bolts from the inside of the cone through the mounting brackets See Figure 10 d Tighten 1 4 20 cone assembly nuts and bolts e For 36 52 and 54 Fans Install the Outside Fan Guard using four 3 8x1 1 4 b...

Page 10: ...place manually open vanes of shutter to access latch Fasten latch located inside fan housing into slot in flange of shutter Firmly lock down latch Repeat procedure to latch opposite side of shutter 8...

Page 11: ...Cumberland 1004 E Illinois St Assumption IL 62510 PHONE 1 217 226 4421 FAX 1 217 226 4420 Manual Part No 4801 5323 Rev 1 2015 Page 11 of 12 MEGA FLOW CON FAN Fan Cone Installation...

Page 12: ...Illinois St Assumption IL 62510 PHONE 1 217 226 4421 FAX 1 217 226 4420 Manual Part No 4801 5323 Rev 1 2015 Page 12 of 12 MEGA FLOW CON FAN Fan Cone Installation Copyright 2015 by The GSI Group LLC P...

Reviews: