2. Installation
PNEG-2348
IR Hopper Sensor Installation
11
IR Plus Feed Sensor Wiring Diagram for Poultry Application
Figure 2C
L1 (Black)
NO (Red)
GND (Green)
L2 (White)
L1 (Black)
NO (Red)
GND (Green)
L2 (White)
1
ON
2
3
4
1
ON
2
3
4
WIRING DIAGRAM FOR FLEX-FLO CONTROL (FLX-4512) TO i-PLUS3 CONTROL BOX (C2000822)
USED AS HOPPER LEVEL CONTROLS FOR POULTRY APPLICATION
i-PLUS3 CONTROL BOX (C2000822)
FEED SENSOR FOR HOPPER #2
i-PLUS3 CONTROL BOX (C2000822)
FEED SENSOR FOR HOPPER #1
RED
BLACK
GREEN
WHITE
L1
GND
L2
230 VAC
POWER
SUPPLY
RED
BLACK
GREEN
WHITE
L1
GND
L2
230 VAC
POWER
SUPPLY
FLEX-FLO
MOTOR
GND
L1
M1 M2
L2
FLEX-FLO CONTROL UNIT