25
Final Start-Up
Regeneration
There are several conditions that will cause the control to trip a regeneration. The “REGEN”
enunciator will light when the control has signaled for a regeneration. The “REGEN” enunciator
will flash while the control is in regeneration. The following are conditions that will call for
regeneration:
1 When the Soft-Minder
®
meter has recorded the passage of a predetermined number of
gallons.
2 When the Aqua-Sensor
®
Probe senses the hardness in the Cullex Media.
3 At the preset time, when the number of days without a regeneration is equal to the Timeclock
Backup setting.
4 At the preset time, when the “REGEN” button is depressed once. “REGEN” will light.
5 Immediately, when the “REGEN” button is depressed for three seconds. “REGEN” will light
and blink.
6 Immediately, if power to the unit has been off for more than 3 hours and time of day has
been restored.