Performance Data
Sheet
Culligan High Efficiency
Twin
10" Upflow Water
Softener with Aqua-
Sensor
®
Sensing Device
Culligan knows the more informed you are about your water treatment systems, the more confident you will be about its
performance. It’s because of this and more than seventy years of commitment to customer satisfaction that Culligan is pro-
viding this Performance Data Sheet to its customers.
NOTICE
Read this Performance Data Sheet and compare the capabilities of this unit with your actual water treatment needs. It
is recommended that before purchasing a water treatment unit, you have your water supply tested to determine your
actual water treatment needs.
Manufacturer:
Culligan International Company
9399 W. Higgins Rd., Suite 1100, Rosemont, IL 60018 USA
(847)
430-2800
Product: Culligan High Efficiency Twin 10” Upflow Water Softener with Aqua-Sensor® Sensing Device
Testing Conditions & Results:
Flow Rate:
9.4 gpm @ 12 psi
Capacity:
30,081 grains @ 6.0 lb. salt
Pressure:
30–40 psi (2.1–2.8 kg/cm2)
47,726 grains @ 12.0 lb. salt
Acidity:
Non-Corrosive
54,975 grains @ 18.0 lb. salt
Temperature:
68°F (20°C)
pH:
7.6
Efficiency Rated Dosage†: 5,014 gr/lb @ 6 lb. salt dosage
Softener Specifications:
Service Flow Rate: 9.4 gpm
Pressure Drop at Max. Flow Rate: 12 psi
Operating Temp. Range: 33-120°F (0.6–51.7°C)
Max. Drain Flow Rate: 2.0 gpm
Working Press. Range: 20–125 psi (1.4–8.5 kg/cm
2
)
Oper. Press. Range (Canada): 20–90 psi (1.4–6.3 kg/cm
2
)
Name of Substance
USEPA Max.
Contaminant Level
pH
Flow Rate
Pressure
Barium
2.0 mg/L
7.5 + 0.5
9.4 gpm
12 (psig)
Radium 226/228
5 pCi/L
7.5 + 0.5
9.4 gpm
12 (psig)
This system is certified for barium and radium 226/228 reduction based on hardness reduction. It is recommended you test
your water every 6 months to ensure the system is performing properly and that hardness, and therefore barium and radium
226/228, are being reduced. Hardness test strips have been included. Additional strips are available from your local Culligan
dealer.
The Culligan High Efficiency Twin 10” Water Softeners with Aqua-Sensor® Sensing Device are tested and certified by WQA
against NSF/ANSI Standard 372, CSA B483.1, NSF/ANSI Standard 44 for the effective reduction of hardness (calcium and
magnesium)
, barium, and radium 226/228,
as verified and substantiated by test data.
An efficiency rated water softener is a DIR softener which also complies with specific performance specifications intended to
minimize the amount of regenerant brine and water used in its operation. Efficiency rated water softeners shall have a rated
salt efficiency of not less than 3350 grains of total hardness exchange per pound of salt (based on NaCl equivalency) (477
grams of total hardness exchange per kilogram of salt), and shall not deliver more salt than its listed rating. The efficiency is
measured by a laboratory test described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can
achieve. Operational efficiency is the actual efficiency achieved after the system has been installed. It is typically less than the
efficiency due to individual application factors including water hardness, water usage, and other contaminants that reduce
the softener’s capacity.
Refer to the Specifications, Familiarization and Warranty section of this Owner’s Guide for more specific product information.
To avoid contamination from improper handling and installation, your system should only be installed and serviced by your
Culligan Man. Performance will vary based on local water conditions. The substances reduced by this system are not neces-
sarily in your water.
Culligan water softeners are designed to work with any salt of good quality, although it is recommended that you ask your
local Culligan Man for his suggestion on the best type and grade of salt to use in this softener.
NOTICE
This softener is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
†
The efficiency rated dosage is only valid at the 6lb. salt dosage and maxmum service flow rate for 10” models.