11
01023052
Drain Facilities
Choose a nearby drain that can handle the rated drain flow (floor drain, sink or stand pipe). Refer to “Ta-
ble 3. Height of Discharge Above Floor Level Operating” on page 22, for maximum drain line length.
NOTE
Most codes require an anti-siphon device or air gap. Observe all local
plumbing codes and drain restrictions. The system and installation must
comply with all state and local laws and regulations.
Electrical Facilities
A 10-foot cord and wall mount plug-in transformer are provided. The customer should provide a recepta-
cle, preferably one not controlled by a switch that can be turned off accidentally. Observe local electrical
codes.
NOTE
The softener works on 24 Volt/60 Hz electrical power only. Be sure to use the
included transformer. Be sure the electrical outlet and transformer are in an
inside location to protect from moisture. Properly ground to conform with all
governing codes and ordinances. Observe all local plumbing codes and drain
restrictions. The system and installation must comply with all state and local
laws and regulations.
NOTE
PN 01020620 and PN 01018133 plug-in transformer are rated for indoor
installations only.