background image

Performance Data

Important Notice:

Read this performance data and compare the capabilities of

this system with your actual water treatment needs.  It is recommended that,
before installing a water treatment system, you have your water supply tested to 
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 42 and 53 for reduction of the
substances listed below.  The concentration of the indicated substances in water
entering the system was reduced to a concentration less than or equal to the per-
missible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

FM-5 with FM-5R Cartridge

Influent Challenge Max. Permissible Product Reduction

Minimum

Average

Substance

Concentration

Water Concentration Requirements

Reduction

Reduction

Standard 42 Aesthetic Effects

Chlorine

2.0 mg/L ± 10%

50%

89.4%

Particulates at least 10,000 particles/mL

85%

99.9%

(0.5 to < 1µm)
Class I
Bacteriostatic

System passes NSF Std. 42 for Bacteriostatic Effects

Taste and Odor

System passes NSF Std. 42 for Taste and Odor Reduction

Standard 53 Health Effects

Cysts

2)

Minimum 50,000/L

99.95%

99.99%

99.99%

Turbidity

11 mg/L ± 1 NTU

0.5 NTU

97.7%

99%

Lead 6.5 pH

0.15 mg/L ± 10%

0.010 mg/L

98%

99%

Lead 8.5 pH

0.15 mg/L ± 10%

0.010 mg/L

98.4 %

99%

Asbestos

10

7

to 10

8

fibers/L > 10

99%

99.95%

99.95%

micrometers in length

Flow Rate = 0.5 gpm (1.9 Lpm) Capacity = 120 gallons (454 L) or 3 months

2)

Based on the use of microspheres or Cryptosporidium parvum oocysts

Testing was performed under standard laboratory conditions, actual performance may vary.

WARNING:  

Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or after the system. Systems
certified for cyst reduction may be used on disinfected waters that may contain
filterable cysts.

NOTE:

Substances reduced are not necessarily in your water. Filter must be

maintained according to manufacturer's instructions, including replacement of filter
cartridges.

NOTE:

The term ‘bacteriostatic’ indicates that the system limits the passage or

growth of bacteria that may already exist in the incoming water. It does not mean
that water leaving the system is safer to drink than water entering the system.

Test Conditions:

Flow Rate: 

0.5 gpm (2.3 Lpm)

Inlet Pressure:

60 psi (4.1 bar)

Ph :

7.5 +/- 0.5

Temperature:

68°F +/- 5°F (20°C +/- 2.5°C)

Operating Requirements

Pressure: 

30–125 psi (2.1 – 8.6 bar)

Temperature:

40 –100°F (4.4–37.8°C)

Turbidity:

5 NTU Max

Suggested Retail Price for Replacement Filter Cartridges: 

FM-5R:

$19.99

NOTE:

Price subject to change. Contact your local retailer or call:

1-888-777-7962 for current replacement cartridge pricing. 

Technical Support: 1-800-645-5426 

(M-F 7:30 am - 5:00 pm CST)

3

State of California

Department of Health Services

Water Treatment Device

Certificate Number

Date Issued: April 19, 2000

Trademark/Model Designation

Replacement Elements

1430

00 -

Culligan FM-5

FM-5R

Manufacturer:

Culligan

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:

Cysts (protozoan)
Turbidity

Asbestos
Lead

None

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems
claiming cyst reduction may be used on water containing cysts.

120 gallons

Rated Service Capacity:

0.5 gpm

Rated Service Flow:

IOWA RESIDENTS ONLY:

Store or seller’s name

Address

City

State

Zip

Telephone

Seller’s signature

Customer’s signature

Date

Summary of Contents for FM-5

Page 1: ...leakage NOTE For cold water use only when in the filtered water position Make certain that installation of this system complies with all state and local laws and regulations The contaminants or other substances removed or reduced by this water treatment device are not necessarily in your water The filter cartridge has a limited service life Changes in taste odor and or flow of the water being filt...

Page 2: ...support at 1 800 645 5426 After filter cartridge is replaced raindrops on filter monitor are still filled in full Remove monitor and press reset button under cap Replace monitor Installing the Filter 4 Unscrew and remove the attachment collar from the filter body Slide the collar over the end of the faucet with threads toward you Screw the adapter you have selected into the faucet and tighten secu...

Page 3: ...ms certified for cyst reduction may be used on disinfected waters that may contain filterable cysts NOTE Substances reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement of filter cartridges NOTE The term bacteriostatic indicates that the system limits the passage or growth of bacteria that may already exist in the incomi...

Page 4: ...which varyfrom state to state Culligan assumes no responsibility for incidental or consequential damages for damages arising out of misuse of the product or the use of any unauthorized attachment Some states do not allow the exclusion or limitation of implied warranties or incidental or consequential damages so the above limitations or exclusion may not apply to you Should service be required duri...

Page 5: ...uando esta filtrando agua Asegúrese de que la instalación cumpla con todas las leyes y regulaciones estatales y locales Los contaminantes u otras substancias que se quitan o se reducen por este aparato para el tratamiento del agua no se encuentran en su agua necesariamente El cartucho filtrante tiene una duración útil limitada Cambios en el sabor olor y o flujo del agua que está filtrando son indi...

Page 6: ...te de atrás del monitor con la flecha encima de la palabra REMOVE en la parte de atrás de cartucho filtrante y suavemente juntelos hasta que oiga un chasquido NOTA asegúrese de alinear las flechas del monitor con el cartucho filtrante o usted puede dañar el monitor NOTA es muy importante fluir el cartucho filtrante nuevo por 10 minutos para quitar los pedazos finos de carbón los cuales son inocuos...

Page 7: ...a filtrante para las necesidades de su agua usted debe obtener un análisis del abastecimiento de su agua para determi nar las necesidades reales Este sistema ha sido probado de acuerdo a las normas NSF ANSI 42 y 53 para la reducción de las substancias indicadas a continuación La concentración de las substancias indicadas en el agua entrante al sistema se redujo a una concentración inferior o igual...

Page 8: ...incidentales consecuentes por daños surgidos por el maltrato del producto o el uso de uniones que no son autorizadas Algunos estados no permiten la exclusión o limitación de garantias implícitas or incidentales o daños consecuentes entonces las limitaciones o exclusiones mencionadas arriba probablemente no le aplican a usted Si su filtro necesita servicio técnico durante o después del tiempo garan...

Reviews: