background image

The FM-5 is Tested and Certified by NSF International to NSF/ANSI Standard 42 for the
aesthetic reduction of Taste and Odor, Chlorine, Particulate Class I and Bacteriostatic
Effects. Standard 53 for the reduction of Cyst, Turbidity, Asbestos and Lead.

Faucet Mount Filter
Use and Care Manual
Model FM-5

Congratulations!

You have purchased a quality Culligan

®

water filter designed to give you cleaner,

better tasting water. For over 60 years, Culligan has been supplying better quality
water to the world. Trust Culligan for the best water you can get, anytime you want
it. Our goal is to provide you with the highest quality water and the best possible
service. For your home. For your health. For your family. 

Operating Specifications

Pressure Range: 

30-125 psi (2.1–8.6 bar) 

Temperature Range: 40–100°F (4.4–37.8°C)
Rated Service Flow:

0.5 gpm at 60 psi (1.9 Lpm @ 4.08 bar)

Filter Capacity:

FM-5: 120 gallons (452 L)

Parts Included 

1. Filter body with "3-way spray" valve handle

157680

2. Filter cartridge

155696

3. Faucet adapters (3 metal with washers)

144736

4. Filter monitor

157810

5. Attachment Collar
6. Gasket and screen (installed in filter body)

Precautions

WARNING:  

Do not use with water that is microbiologically unsafe or of

unknow quality without adequate disinfection before or after the system. Systems
certified for cyst reduction may be used on disinfected waters that may contain
filterable cysts.

CAUTION:

This filter must be protected from freezing, which can cause cracking

of the filter and water leakage.

NOTE: 

•  For cold water use only (when in the filtered water position).
•  Make certain that installation of this system complies with all state and local

laws and regulations.

•  The contaminants or other substances removed or reduced by this water

treatment device are not necessarily in your water.

•  The filter cartridge has a limited service life. Changes in taste, odor, and/or

flow of the water being filtered indicate that the cartridge should be replaced.

•  After prolonged periods of non-use (such as during a vacation), it is

recommended that the system be flushed thoroughly. Let water run for 5
minutes before using.

Selecting the Correct Faucet
Adapter

(1)

From the adapter kit, select the large adapter with the internal threads (Fig.1).  

(2)

Select one of the larger rubber washers and place it securely inside of the larg-
er adapter (Fig. 2).

(3)

Remove the aerator from your faucet and determine the type of faucet threads:

A. External threads:

Use the larger adapter and washer by themselves.

B. Internal threads:

Through trial and error, select the smaller adapter (with

external threads) that fits your faucet. Make sure there is a washer located
inside the larger adapter, then screw the smaller adapter into the large
adapter and tighten it securely. (Fig. 3).

NOTE:

Adapters are included which will fit most faucets. To create a tight seal, you

may need to use the gasket from your faucet’s aerator in addition to the washers
included with the adapters.  If the adapters do not fit, it is recommended that you
consult your local plumbing or hardware supplier for assistance in obtaining the
correct thread adapter.

2

1

3

4

5

6

11/03   145880   Rev B

2

3

1

Technical Support: 1-800-645-5426 

(M-F 7:30 am - 5:00 pm CST)

1

Summary of Contents for FM-5

Page 1: ...leakage NOTE For cold water use only when in the filtered water position Make certain that installation of this system complies with all state and local laws and regulations The contaminants or other substances removed or reduced by this water treatment device are not necessarily in your water The filter cartridge has a limited service life Changes in taste odor and or flow of the water being filt...

Page 2: ...support at 1 800 645 5426 After filter cartridge is replaced raindrops on filter monitor are still filled in full Remove monitor and press reset button under cap Replace monitor Installing the Filter 4 Unscrew and remove the attachment collar from the filter body Slide the collar over the end of the faucet with threads toward you Screw the adapter you have selected into the faucet and tighten secu...

Page 3: ...ms certified for cyst reduction may be used on disinfected waters that may contain filterable cysts NOTE Substances reduced are not necessarily in your water Filter must be maintained according to manufacturer s instructions including replacement of filter cartridges NOTE The term bacteriostatic indicates that the system limits the passage or growth of bacteria that may already exist in the incomi...

Page 4: ...which varyfrom state to state Culligan assumes no responsibility for incidental or consequential damages for damages arising out of misuse of the product or the use of any unauthorized attachment Some states do not allow the exclusion or limitation of implied warranties or incidental or consequential damages so the above limitations or exclusion may not apply to you Should service be required duri...

Page 5: ...uando esta filtrando agua Asegúrese de que la instalación cumpla con todas las leyes y regulaciones estatales y locales Los contaminantes u otras substancias que se quitan o se reducen por este aparato para el tratamiento del agua no se encuentran en su agua necesariamente El cartucho filtrante tiene una duración útil limitada Cambios en el sabor olor y o flujo del agua que está filtrando son indi...

Page 6: ...te de atrás del monitor con la flecha encima de la palabra REMOVE en la parte de atrás de cartucho filtrante y suavemente juntelos hasta que oiga un chasquido NOTA asegúrese de alinear las flechas del monitor con el cartucho filtrante o usted puede dañar el monitor NOTA es muy importante fluir el cartucho filtrante nuevo por 10 minutos para quitar los pedazos finos de carbón los cuales son inocuos...

Page 7: ...a filtrante para las necesidades de su agua usted debe obtener un análisis del abastecimiento de su agua para determi nar las necesidades reales Este sistema ha sido probado de acuerdo a las normas NSF ANSI 42 y 53 para la reducción de las substancias indicadas a continuación La concentración de las substancias indicadas en el agua entrante al sistema se redujo a una concentración inferior o igual...

Page 8: ...incidentales consecuentes por daños surgidos por el maltrato del producto o el uso de uniones que no son autorizadas Algunos estados no permiten la exclusión o limitación de garantias implícitas or incidentales o daños consecuentes entonces las limitaciones o exclusiones mencionadas arriba probablemente no le aplican a usted Si su filtro necesita servicio técnico durante o después del tiempo garan...

Reviews: