![Culligan 10](http://html.mh-extra.com/html/culligan/10/10_owners-manual_2697726004.webp)
4
01023052
Culligan High Efficiency Twin Water Conditioners with
Aqua-Sensor
®
Device or Soft-Minder
®
Meter—Downflow Regeneration
Model
9" Model
10" Model
12" Model
14" Model
Control Valve
1” Reinforced Thermoplastic w/ HE Circuit Boards
Overall Conditioner Ht
56 in
62 in
60 in
73 in
Media Tank Design
Quadra-Hull
™
Media Tank Dimensions
(Dia x Ht)
9 x 48 in
10 x 54 in
12 x 52 in
14 x 65 in
Salt Storage Tank
Dimensions (Dia x Ht)
18 x 43 in
18 x 43 in
18 x 43 in
24 x 42 in
Exchange Media, Type
and Quantity
Cullex
®
Media, 1.0 ft
3
Cullex Media, 1.5 ft
3
Cullex Media, 2.0 ft
3
Cullex Media, 3.0 ft
3
Underbedding, Type and
Quantity
Cullsan
®
Underbedding, 12 lb
Cullsan
Underbedding, 15 lb
Cullsan
Underbedding, 20 lb
Cullsan
Underbedding, 25 lb
Exchange Capacity @ Salt
Dosage Per Recharge
17,854 gr @ 4.0 lb
26,781 gr @ 6.0 lb
31,352 gr @ 7.0 lb
51,726 gr @ 12 lb
27,108 gr @ 8.0 lb
40,662 gr @ 12.0 lb
48,458 gr @ 16.0 lb
75,582 gr @ 24 lb
31,736 gr @ 12.0 lb
47,604 gr @ 18.0 lb
59,267 gr @ 18.0 lb
88,549 gr @ 36 lb
Efficiency rated dosage
1
4,463 gr/lb @ 4 lb
salt dosage
4,463 gr/lb @ 6 lb
salt dosage
4,479 gr/lb @ 7 lb
salt dosage
4,310 gr/lb @ 12 lb
salt dosage
Freeboard to Media
2
14.5 in
14.5 in
16 in
25 in
Freeboard to
Underbedding
3
44.5 in
47.5 in
46 in
59 in
Salt Storage Capacity
375 lb
375 lb
375 lb
600 lb
Rated Service Flow @
Pressure Drop
9.0 gpm @ 11 psi
9.4 gpm @ 12 psi
10.0 gpm @ 10 psi
10.6 gpm @ 11 psi
Auxiliary Flow Rate
4
10.8 gpm @ 15 psi
11.0 gpm @ 15 psi
12.6 gpm @ 15 psi
12.8 gpm @ 15 psi
Total Hardness, Maximum
75 gpg
99 gpg
99 gpg
99 gpg
Total Iron, Maximum
5 ppm
Hardness to Iron Ratio,
Minimum
8 gpg to 1 ppm
Operating Pressure
20-125 psi [138–862 kPa]
Operating Pressure
(Canada)
20-90 psi [138–621 kPa]
Operating Temperature
33-120°F [0–49°C]
Electrical Requirements
24V/60 Hz
Electrical Power
Consumption, Min/Max
8.4 watts/21.6 watts
Drain Flow, Maximum
5
2.5 gpm
2.5 gpm
3.0 gpm
5.3 gpm
Recharge Time, Average
6
Recharge Water
78 minutes
67 minutes
62 minutes
76 minutes
Consumption, Average
6
47 gallons
45 gallons
67 gallons
155 gallons
1 The efficiency rated dosage is only valid at the stated salt dosage and is efficiency rated according to NSF/ANSI Standard 44.
2 Measured from top of media to top surface of tank threads (backwashed and drained).
3 Measured from top of underbedding to top surface of tank threads.
4 Auxiliary flow rates do not represent the maximum service flow rate used for determining the softener’s rated capacity and
efficiency and that continuous operation at these flow rates greater than the maximum service flow rate may affect capacity and
efficiency performances.
5 Backwash at 120 psi.
6 10 minute backwash, 4 lb. 9” model, 6 lb. 10” model, 7 lb. 12” model, or 12 lb. 14” model salt dosage.
Specifications