37
Gap/Black Mark
Sensor Calibratio,
Label Length
Measurement, Self
Test and enter Dump
Mode
1.Turn off the power switch.
2. Hold the feed button while turning on the power switch.
3. Release the button when LED becomes
amber
and
blinking. (Any amber will do during the 5 blinks).
The LED color will be changed as following order.
Amber
Æ
red (5 blinks)
Æ
amber (5 blinks)
Æ
green (5 blinks)
Æ
green/amber (5 blinks)
Æ
red/amber (5 blinks)
Æ
solid green
It calibrates the sensor and measures the label
length and prints internal settings then enter the
dump mode.
Note:
Please select gap or black mark sensor by using the
GAP or BLINE command prior to sensor calibration.
Printer Initialization
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns
green
after 5 amber
blinks.
(Any green will do during the 5 blinks).
The LED color will be changed as following:
Amber
Æ
red (5 blinks)
Æ
amber (5 blinks)
Æ
green (5 blinks)
Æ
green/amber (5 blinks)
Æ
red/amber (5 blinks)
Æ
solid green
Note:
Always do gap/black mark sensor calibration
after
printer initialization.
Black Mark Sensor
Calibration
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when LED turns
green/amber
after 5
green blinks.
(Any green/amber will do during the 5
blinks).
The LED color will be changed as following:
Amber
Æ
red (5 blinks)
Æ
amber (5 blinks)
Æ
green (5 blinks)
Æ
green/amber (5 blinks)
Æ
red/amber (5 blinks)
Æ
solid green