background image

1. INTRODUCTION 

 

Thank you for using the 7x10/100TX plus 2x100FX managed converter switch.  The built-in 
management module allows user to configure this managed converter switch and monitor 
the operation status locally or thru network remotely.   

 

1.1 Management Options 

 

 

 
 
 

 

 

 

 

 

 

 

 

 

 

      

LED 

Fig. 1 Front Panel 

 

RS-232 

Duplex SC  
Connector 

       

 

 

 

 

 

Fig. 

Back 

Panel 

 

        

 

 

 

 

 
Management switch are available options are listed below: 

  Local Console Management 

 Telnet 

Management 

 SNMP 

Management 

 

Local Console Management 

 
Local Console Management is done through the RS-232 DB-9 console port located at the 
front of the converter switch.  Direct RS-232 cable connection between the PC and the 
converter switch is required for this type of management. 
 

Telnet Management 

 
Telnet is done through the network.  Once the converter switch is on the network with proper 
configuration, you can use Telnet to log in and monitor the status remotely. 

 
SNMP Management 

 

SNMP is also done over the network.  Besides standard MIB (Management Information 
Bases), an additional private MIB is also provided for SNMP-based network management 
system to compile & control. 

Summary of Contents for swh-2109

Page 1: ...SWH 2109 7 x 10 100Base TX to 2 x 100Base FX Managed Converter Switch Network Management User s Guide Ver 1 4 1...

Page 2: ...ment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or mo...

Page 3: ...2 8 Switch Management 28 2 8 1 Switch Configuration 29 2 8 2 Priority and Rate limit Configuration 30 2 8 3 Port Configuration 32 2 8 4 VLAN Configuration 33 2 8 4 1 Port Based VLAN Configuration 34 2...

Page 4: ...t Local Console Management Local Console Management is done through the RS 232 DB 9 console port located at the front of the converter switch Direct RS 232 cable connection between the PC and the conv...

Page 5: ...software to the converter switch RS 232 DB 9 console port directly Or you can use Telnet to login and access the Console Program through network connection remotely SNMP Management Systems You can us...

Page 6: ...nal copper based Ethernet Fast Ethernet devices into network All these ports support auto negotiation and MDI MDIX auto crossover i e either crossover or straight through CAT 5 cable may be used RS 23...

Page 7: ...operate A subnet mask is a filtering system for IP addresses It allows you to further subdivide your network You must use the proper subnet mask for proper operation of a network with subnets defined...

Page 8: ...lly when the network is down and the converter switch cannot be reached by any other means You also need to use the Local Console Management to setup the converter switch network configuration for the...

Page 9: ...e IP address for the first time Follow these steps to manage the converter switch through Telnet session 1 Use Local Console to set up the assigned IP parameters of the converter switch IP address Sub...

Page 10: ...sword then press ENTER to login to the Console Program main menu Press Tab or or or Number directly to select 1 System Information Name the converter switch specify the location and check the current...

Page 11: ...h port configuration VLAN configuration and other functions 5 Switch Monitor View the operation status and traffic statistics of the ports 6 System Utility Ping Firmware Upgrade Load Factory Setting e...

Page 12: ...ice field Spacebar Select within Pull Down Menu in a choice field or Toggle between available options in a choice field Spacebar Move to the next entry field or command Tab Move one line up to the pre...

Page 13: ...selection and then press Spacebar to select 3 Toggle Option XXXX A Toggle option contains 2 selections for example Account State Press Spacebar to select between Enable Disabled 4 Editing Field XXXX...

Page 14: ...quit the current menu 8 Help Press Help to view On Line help as below This pop up message alerts user that the configuration change will take effect after reset However before perform System Reset use...

Page 15: ...up to 55 alphanumeric characters Use a descriptive name to identify the converter switch in relation to your network for example Backbone 1 This name is mainly used for reference purpose only System L...

Page 16: ...iver connector type 2KM fiber transceiver operation length TP Port View only field shows the total TP port number Boot ROM Version View only field shows the Boot ROM version OS Version View only field...

Page 17: ...erate the converter switch need to register into the user list first To view or change current registered users select 2 User Authentication from the main menu following screen appears Up to 10 Users...

Page 18: ...r a unique description for the User up to 35 alphanumeric characters This is mainly for reference purpose only IP Security Press Spacebar to Enable or Disable the IP security function If Enable user m...

Page 19: ...fy user account system information cannot load factory setting Read Only Allow to view only Access Denied Complete forbid to access NOTICE To prevent un caution operation a user cannot Delete Modify U...

Page 20: ...Management Enable or Disable the specified network services 3 RS232 Telnet Console Configuration View the RS 232 port setting specified Telnet Console services 4 Device Community View the registered...

Page 21: ...pecify the IP address Subnet Mask Gateway IP Address Enter the unique IP address of this converter switch You can use the default IP address or specify a new one if there is address duplication or the...

Page 22: ...w only field shows currently assigned by DHCP or manual IP address Subnet Mask Gateway of the converter switch 2 7 2 System Service Management Select option System Service Management from the Network...

Page 23: ...ty Check None RS 232 setting view only field Word Length 8 RS 232 setting view only field Flow Control None RS 232 setting view only field Telnet Port Specified the desired TCP port number for the Tel...

Page 24: ...gement menu following screen appears Up to 10 Device Community maybe set Use Delete to remove a registered community Press New to add a new community Press Edit to view the current community setting F...

Page 25: ...ty Press Spacebar to Enable or Disable the IP security function If Enable Community may access the converter switch only through the management station which has exact IP address specified in below IP...

Page 26: ...ement menu following screen appears State Enable or Disable to send Trap to the specified destination Destination Enter the specified IP address of the network management system that will receive the...

Page 27: ...rt Trap Enable or Disable the converter switch to send Warm Start trap after system reset Authentication Failure Trap Enable or Disable the converter switch to send Authentication Failure trap after a...

Page 28: ...nsole main menu following screen appears 1 Switch Configuration Setup acceptable frame size and address learning etc 2 Priority and Rate Limit Configuration Enable Disable Port priority and setup Port...

Page 29: ...conds Fiber Port Redundancy SWH 2109 has two Fiber ports can set up redundancy each other Use spacebar choice enable disable in Restart position If specify enable then the Port 8 Media Type Copper wou...

Page 30: ...use 802 1Q tag value as frame passing in switch priority IP TAG mean IP TOS priority has higher precedence while work with TAG Priority TAG IP are vice versa Schedule Mode Use spacebar select Weight 8...

Page 31: ...otalBits mean a complete frames it longer than Framebits TotalBits IFG mean TotalBits add Inter Frame Gap It is longer than TotalBits This field provides rate limit more selectable options Port Ingres...

Page 32: ...Using spacebar to select All port 1 port 2 and port 3 Port State Enable or disable current port state Port Type Press Spacebar to choice Auto Negotiation manual 10M bps and Half Flow Control Press sp...

Page 33: ...hysical location End nodes that frequently communicate with each other are assigned to the same VLAN regardless of where they are physically on the network Another benefit of VLAN is that you can chan...

Page 34: ...ort Based VLAN is uncomplicated and fairly rigid in implementation it is best used for network administrators who wish to quickly and easily setup VLAN in order to isolate the effect of broadcast pack...

Page 35: ...VLAN Name Use default name or specify a VLAN name VLAN Members Moving cursor to VLAN member mark with V to denote which port belong to VLAN 35...

Page 36: ...cal Redundancy Check Important VLAN Concepts for Configuration There are two key components to understanding The Default Port VLAN ID PVID which specifies the VLAN to which the switch will assign unla...

Page 37: ...he frame 2 If a tagged frame is received the VID in the frame tag is used If Ingress Filtering is Enable and the switch will first determine 1 If the ingress port itself is a member of the frame VLAN...

Page 38: ...l packets that flow into and out of it If a packet has previously been tagged the port will not alter the packet thus keeping the VLAN information intact The VLAN information in the tag can then be us...

Page 39: ...802 1Q VLAN configuration Press New to add a new VLAN entity Press Edit to view the current VLAN setting Use Delete to remove a VLAN entity Following screen appears if you choice IEEE 802 1Q Tag VALN...

Page 40: ...fy a VLAN ID VLAN Name Use default name or specify a VLAN name VLAN Members Moving cursor to VLAN member mark with V to denote which port belong to VLAN And the following screen appears if you choice...

Page 41: ...ting of VLAN table When VLAN table exists the packet will follow up the VLAN table If not the packet broadcasts and follows up Port Based VLAN Check If receive a packet without Tag the packet follows...

Page 42: ...N mode is disabled the Egress packet will be untagged T When VLAN table dose not exist or VLAN mode is disabled the Egress packet will be tagged with Ingress PVID D Force to add one tag with Ingress P...

Page 43: ...the Console main menu following screen appears 1 Switch Port State View current port media type port state etc 2 Port Traffic Statistics View port Receive Send Byte Frames utilization etc 3 Port Packe...

Page 44: ...following screen appears Port Number The number of the port Media Type The media type of the port could be TP or Fiber Link State The current link status of the port could be Up or Down Speed Mbps Th...

Page 45: ...Total bytes received from current port Frames Received Total frames received from current port Utilization real port traffic ratio to current port total bandwidth Bytes Sent Total bytes sent from curr...

Page 46: ...ng bits but including FCS between 64 and 1522 bytes inclusive and have a bad FCS with an integral number of bytes RX Fragments Total frames received which were less than 64 bytes or frames without SFD...

Page 47: ...l frames received had both Oversize CRC error RX Dropped frames Total received frames dropped due to resources shortage TX Dropped frames Total frames not transmitted due to resources shortage TX Late...

Page 48: ...65 127 bytes frames received RX frames 128 255 Total 128 255 bytes frames received RX frames 256 512 Total 256 512 bytes frames received RX frames 512 1023 Total 512 1023 bytes frames received RX fra...

Page 49: ...able MAC address table display MAC addresses learned since reset system and MAC address learning enable Above table mean MAC addresses learn from each port of the switch Press U to Update Table Press...

Page 50: ...user to ping a specified network device 2 Update Firmware Allow user to update the latest firmware save current configuration or restore previous configuration to the converter switch 3 Load Factory S...

Page 51: ...ing Except Network Configuration Select this will also return the configuration of the converter switch to the factory default settings However this will not return the IP and Gateway addresses to the...

Page 52: ...y the network connection Select Ping from the System Utility menu following screen appears IP Address Enter the desired IP address that the converter switch will Ping Size Enter the desired length of...

Page 53: ...2 10 2 Event Log Event log keep tract of user login logout timestamp Select Event Log from the System Utility menu following screen appears 53...

Page 54: ...n the File Server File Location Enter the specified path file name within the File Server Select Get then press Enter to start the download process receive file from the server A Transmitting Progress...

Page 55: ...nclude the IP and Gateway address Load Factory Setting is useful when network administrator like to re configure the system A system reset is required to put all changes effect after Load Factory Sett...

Page 56: ...tory default Load Factory Setting Except Network Configuration is extremely useful when a network administrator need to re configure the system REMOTELY Because traditional Factory Reset will bring ne...

Page 57: ...configuration setting permanently user need to save configuration first before reset the converter switch Select Save Configuration from the Console main menu following screen appears To save the Con...

Page 58: ...2 Reset System After configuration change reset system to take change effect Select Reset System from the Console main menu following screen appears To perform System Reset Select OK then press Enter...

Page 59: ...le Logout will stop current RS 232 or Telnet connection between the system and the PC To perform Logout select option Logout from the Console main menu following screen appears To logout select OK the...

Page 60: ...memory resources required for the complete network management SNMP Manager often composed by desktop computer work station and software program such like HP OpenView Totally 4 types of operations are...