Current:
Current registered community number.
Total:
Total registered community user number.
Max Users: Maximum available registered community number, default 10.
Account State:
Press Spacebar to Enable or Disable this Community Account.
Community:
Specified the authorized SNMP community name, up to 20 alphanumeric
characters.
Description:
Enter a unique description for this community name, up to 35 alphanumeric
characters. This is mainly for reference purpose only.
IP Security:
Press Spacebar to Enable or Disable the IP security function.
If Enable, Community may access the converter switch only through the management
station, which has exact IP address specified in below IP address field.
If Disabled, Community may access the converter switch through any management station.
IP Address:
Specify the IP address used for IP Security function.
SNMP Level:
Use
or
to select desired privilege for the SNMP operation
NOTICE:
If the community browses the converter switch without proper access right, the converter
switch will respond empty. For example, if a community only had Read & Write privilege
then it cannot browse converter switch User table.