Assumed that we have a setting of existing User Previlidge in DUT and a configure file ready to be
loaded.
Here is the treatment of User Privilege of configure restoration:
A. Save the existing homeuser configuration in DUT
B. Reset the DUT back to default setting.
C. Check the write protection level. If the write protection level is
“home”, it loads DUT’s homeuser
configure back into DUT.
To overwrite all of configuration, please change the write protection level
“home” into “editor”.In
terms of User Previlidge. If the write protection level is
“editor”, it loads the homeuser of new
homeuser configure file into DUT
3.14 Factory Default
Select
Factory Default
from menu bar. Then,
Factory Default
screen page will appear as follows:
3.14.1 Factory Default
Load Factory Setting
will set all the configurations of the Gateway back to the factory default
settings, including the IP and Gateway address.
Load Factory Setting
is useful when network
administrators would like to re-configure the system. A system reset is required to make all
changes effective after Load Factory Setting.
Load Factory Settings Except Network Configuration
will set all the configurations of the
Gateway back to the factory default settings. However, IP and Gateway addresses will not restore
to the factory default. It is very useful when network administrators need to re-configure the
Existing DUT User
Previlidge Accounts:
1. Superuser
2. Editor
3. Homeuser
New Configure file of User
Previlidge Accounts::
1. Superuser
2. Homeuser
Write Protection
Level
“home”
Write Protection
Level
“editor”