5
Installation – Relay
Status LEDs
Green
lights up when relay is ON
Blue
flashes
when data is received from paired units (e.g. sensor)
Blue +
Green
flash
alter-
nately
1 minute after emergency mode is activated and
continue to flash while the product is in emergency
mode (12 hours).
Red
flashes
if relay overheats – relay is turned OFF
Red
f
beeping
if there is an error, e.g. external switch paired before
sensor
Yellow lights up when cooker’s electricity consumption exceeds 1.2 A
**
Yellow flashes
in pairing mode
*
emergency mode = all safety functions deactivated. See page 15.
**
1.2 A is the factory default. After calibration, the LED lights up when the
new setting is exceeded (page 12)
If there is no radio communication from the sensor, the relay will shut off after
5 minutes.
Other functions
Hold the button on the relay in for the desired function
Time
Release button when Function
40 ms - 1 s (short press)
Pairing
3 s - 5 s
Red light up Pairing signal to HUB
5 s - 8 s
Yellow lights up,
Red has gone out
Number of devices paired. When the button
is released, this is shown by the number
of yellow flashes
10 s - 12 s
Red + Green flash
Calibrating electricity consumption
15 s - 20 s Red flashes
Reset and deletion of paired devices. Relay is
turned off if it was on
20 s +
All LEDs go out
Cancel/no setting changed