12
Installation – Settings
DIP 3 Installation angle
De-
fault
OFF
0 - 450 (sloping
ceiling)
ON
00 (flat ceiling)
DIP 4 DIP 5
Installation height
above hob
De-
fault
OFF
OFF
70 - 104 cm
ON
OFF
105 - 149 cm
ON
ON
150 - 194 cm
OFF
ON
195 - 210 cm
DIP 3: Installation angle
DIP 4 and 5: Installation height
DIP 6 and 7: Timer function
The countdown starts when
the cooker is turned on. When
5 minutes of the set time are left,
the cooker guard beeps once
every 15 seconds for 5 minutes.
Pressing the control button
restarts the countdown.
DIP 6
DIP 7
Minutes
De-
fault
ON
ON
Off
OFF
ON
45 min.
ON
OFF
120 min.
OFF
OFF
240 min.
DIP 8: Current measurement
NB! Turning current measurement
OFF will reduce battery life
considerably. Should only be
deactivated if an external power
supply is used.
Calibrating electricity consumption
If the yellow LED on the relay comes on continuously while the hob is
OFF and does not disappear when the control button on the sensor is
pressed, the standby current to the cooker is higher than the cooker guard’s
preprogrammed standby level.
In this case the level can be recalibrated to actual electricity consumption by:
1.
Holding the relay’s control button in until the red and green LEDs flash –
then releasing the button within two seconds.
2. The green LED flashes three times to acknowledge the change.
NB: We strongly recommend measuring the hob’s electricity consumption
in standby BEFORE doing this calibration. High electricity consumption
could be caused by a fault in the hob. Incorrect calibration in the case of high
electricity consumption can result in the cooker guard never starting or not
working as intended.
NB! May only be carried out
by an authorised electrician.
DIP 8
Current measurement
De-
fault
OFF
Current measurement off
ON