Chapter 1. Introduction
1-7
Multiplexer Unit : Apr 2003
Optical Specifications (redundant fiber has identical specifications as primary)
Standard Types
WDM Types*
Type
M-M
S-M
S-M
S-M
S-M
S-M
S-M
S-M
S-M
Distance (Km)
2
15
30
50
120
20(A)* 20(B)* 40(A)* 40(B)*
Tx:1310 Tx:1550 Tx:1310 Tx:1550
Wavelength
(nm)
1310
1310
1310
1310
1550
Rx:1550 Rx:1310 Rx:1550 Rx:1310
BER
<10
-10
<10
-10
<10
-10
<10
-10
<10
-10
<10
-10
<10
-10
<10
-10
<10
-10
Sensitivity
-31dBm -32dBm
-35dBm
-36dBm
-35dBm
-32dBm
-32dBm
-32dBm
-32dBm
Output Power
-20dBm
-20dBm
-15dBm
-8dBm
-7dBm
-18dBm
-15dBm
-10dBm
-7dBm
Power Margin
11dBm
12dBm
20dBm
28dBm
28dBm
14dBm
17dBm
22dBm
25dBm
Return Loss
-12dBm
-12dBm
-12dBm
-12dBm
-12dBm
-14dBm
-14dBm
-14dBm
-14dBm
ST
v
v
v
v
v
SC
v
v
v
v
v
v
v
v
v
LC
v
v
v
v
v
MT-RJ
v
v
v
v
v
Conn.
Types
FC
v
v
v
v
v
M-M: multi- mode S-M: single- mode
* WDM types must match (A) with (B) in pairs
All fiber transceivers in the Multiplexer incorporate an automatic laser shutdown feature (ALS)
designed to protect personnel that may come into contact with a disconnected fiber connection. This
feature may also be disabled for testing purposes via the front panel LCD, console terminal mode or
SNMP (when SNMP option is installed).
Physical
Height:
43 mm (1.75")
Width:
438 mm (17.25")
Depth:
251 mm (9.875")
Weight:
4.5 kg (10 lb.) Net
Power supply
Voltage (AC source)
90 ~ 250 VAC
Voltage (DC source)
20 ~ 60 VDC
Frequency
47 to 63 Hz for AC power
Power consumption
40 VA
Environment
Temperature
0-50
°
C / 32-122
°
F
Humidity
0 to 90% non-condensing
Summary of Contents for FMUX-01
Page 1: ......
Page 2: ......
Page 16: ...Chapter 1 Introduction 1 10 Multiplexer Unit Apr 2003 This page left blank intentionally...
Page 55: ...notes A 7...
Page 56: ...notes A 8...
Page 58: ......
Page 59: ......