32
CTC EcoLogic M/L
i
Tip: Set to "Economy" mode from
the start. If the hot water is deemed
insuffi cient, raise to "Normal" mode,
and so on.
4.4
DHW
The "Extra DHW" function is set to be active for 3.5 hours.
i
Tip: Set the time about one hour
earlier than when you need the hot
water as it may take some time to
heat.
Economy
For low hot water needs.
(Factory setting stop temperature DHW tank:
50
°C
).
Normal
Normal hot water needs.
(Factory setting stop temperature DHW tank:
55
°C
).
Comfort
For high hot water needs.
(Factory setting stop temperature DHW tank:
58
°C
).
The "Extra DHW" function is set to be active on weekdays
between 06:30 and 07:30.
This menu is used to set the hot water comfort level and
"Extra DHW".
Extra DHW
The "Extra DHW" function can be activated here. When
the function is activated (by setting the number of hours
using the plus sign in the "Hot Water" menu), the heat
pump immediately starts to produce extra DHW. It is
also possible to remotely control or schedule hot water
production according to specifi ed times.
DHW mode
You set the values for this option which apply to the heat
pump’s normal operation. There are three modes:
4.4.1
Extra DHW
You can use this menu to schedule periods during
weekdays when you want extra DHW. This schedule is
repeated every week.
The stop temperature for Extra DHW is 60 °C (factory
setting).
The "Weekly Program" chapter describes how to set
schedules.
Click the "Extra DHW schedule" heading to obtain a
graphical overview of when the weekly program is active
during weekdays.
Use the Back button to switch between settings and preview.
A vertical blue bar indicates when "Extra DHW" is active. A
horizontal yellow line indicates the current time. The X axis
represents the days, Monday to Sunday.