Installation
This chapter turns to you who are responsible for the necessary installations in order to give
the EcoEl such an operation as the house owner demands.
Take time going through functions, controls, knobs and settings together with the end user
and answer eventual questions. Both you and the heat pump benefits from a well informed
end user regarding operation and maintenance of the heat pump.
Transport
To avoid transport damages, do not unpack the product until it has been transported
to its installation site in the product room. The EcoEl can be handled and lifted in the
following way:
◗
Fork truck.
◗
Lifting eye to be fitted to the lifting sleeve on top of the product
(extra sleeve can be found on top of the product in the center under the insulation).
◗
Lifting band around the pallet. Note! Only with the wrapping on.
Consider that the heat pump has a high gravity, handle with caution.
Unpacking
Unpack the heat pump when it is placed next to its installation site. Check that the
product has not been damaged during transport. Report eventual damages to the
forwarding agent. Also check that the delivery is complete according to the list below.
Standard delivery
◗
Electrical boiler CTC EcoEl (concerning the CTC EcoEl 1550 the heat carrier pump is
being delivered factory mounted)
◗
Enclosed bag with:
- indoor sensor
- primary flow sensor
- outdoor sensor
- installation and maintenance instructions
- safety valve for DHW, 9 bar
- safety valve for the brine system, 3 bar
Hydraulic installation
The installation must be carried out in accordance with existing engineering standards
and building regulations. The product must be connected to an expansion vessel in an
open or closed system. Do not forget to flush the radiator system clean before connec-
tion. Do all installation-adjustments according to the description in chapter First start.
Connections, placement and dimensions
See Measurements.
Pipe connections of the product
Connect the pipes according to the principle sketch for pipe connection on the follo-
wing page. See also Measurements on page for placements and dimensions of the con-
nections.
Circulation pump radiator system
The circulation pump is to be fitted on the primary flow pipe to the radiator system,
The pump is to get its power supply from the CTC EcoEl, see Wiring diagram.
Installation
!
The product must be
vertically positioned
when transported and
kept in stock.