CTC EcoEl
End user information
21
Menu Settings
(
Installer/Settings
)
In the menu“Settings”, the installer and user make the adjustments to the
requirements and demands.
U = settings made by the user.
I = settings made by the installer.
Lang. English
I/B.
Setting the language.
Product EcoEl
I.
The control unit contains control systems to several product types: Eco Heat, EcoPart,
EcoEl and EcoAir. The correct product is set by the factory. If EcoEl is supplemented with
EcoPart or EcoAir, the product type must be changed.
Indoor sens. Yes/No
I.
Select here whether an indoor sensor is to be included in operation. An indoor sensor can
be temporarily deselected, for example when a fire place is being used.
Boiler °C 50
I/B.
The electric unit’s temperature is set here. A low setting is recommended. The electric
unit is also responsible for peak heating. If the house requires a higher temperature than that
selected, the control system compensates by automatically raising the temperature.
Boiler max kW 3
I.
Setting determining the electric unit’s maximum permitted power.
0 to 9 kW with steps of 1.5 kW.
Boiler lower °C 50
I.
Setting the temperatur of the lower part of boiler.
Boiler lower kW 3
I.
Setting the lower part of the boilers maximum permitted power. 0 to 9 kW with steps of
1.5 kW.
Main fuse A 20
I.
The house’s main fuse size is set here. This setting and the fitted current sensors ensure
the fuses are protected when using equipment which generates temporary power peaks, for
example cookers, ovens, engine heaters etc. The product temporarily reduces power drawn
where this type of equipment is being used.
External control NS
I.
Selection of remote control type. NR = remote controlled temperature lowering, for
example via the minicall system. SO = electricity supplier control. Disconnection of com
pressor and electric cartridge for specific periods of time as determined by the electricity
supplier (special equipment is required).
Setting house
I/B.
When this is selected, a sub menu will be displayed in which the house’s temperature
Paramet.
requirement (heating curve) is set, see the “House parameters” menu.
Holiday D On/Off
B.
Where you require constant night time lowering of temperatures (for example when on
holiday), the number of days (holiday) can be set here. Up to 250 days can be set. Off = not
activated.
Prim red °C -2
B.
Here you can set how many degrees the room temperature is to be lowered during
the lower temperature periods. NB: –5 means that the room temperature is lowe
red 5°C below the ordinary temp. If the room sensor is not included in operation,
the lowering is applied to the primary flow temperature. Rule of thumb: a 3–4°C
lower primary flow temperature gives around 1°C lower room temp in a normal
system.
Settings
Lang.
English
Product
EcoEl
Indoor sens
Yes/No
Boiler °C
50
Boiler max kW
3
Boiler lower °C
50
Boiler lower kW
3
Main fuse A
20
External Control
NS
Setting house paramt
Holiday
On/Off
Prim red °C
-2
HP max DHW
Yes
Save setting
Load setting
Load factory setting