CTC EcoEl
End user information
19
Menu Stored operation data
(the menu can be directly accessed from the main menu)
Operation values across longer periods of time are reported in this menu.
Total Operation h
Displays the total time the product has been connected to power.
El heat kWh
Displays the product’s total calculated approximate consumption.
This is not a direct energy measurement. The household energy is outside this
display.
Max prim °C 55
Displays the maximum temperature of the water supplied to the radiators.
The value can indicate the radiator system/the house’s temperature requirement.
The lower the value in the winter season, the better the system is adapted to heat
pump operation.
The value can be reset by pressing the “OK” button in this menu.
Menu Night reduction
(the menu can be directly accessed
from the main menu)
Night time lowering of temperatures can be activated and set in this menu.
Night time temperature lowering means that the indoor temperature is lowered
during scheduled periods, for example at night or when you are at work. Two
types of night time temperature lowering can be selected. Week Program is se-
lected to schedule daily lowering of temperatures. Block is selected to schedule
night temperature lowering periods which last for several days.
Activated Yes/No
Here you can select whether scheduled temperature lowering is active. Where “
No
”
is selected, there is no temperature lowering.
Typ WeekProgram
The type of lowering is selected here:
WeekProgram
means that periods of lower temperatures can be scheduled for all
days of the week, with the option of two periods of lower temperatures per day.
The schedule repeats every week.
Block
means that lowering is scheduled for several days of the week, for example
Monday to Friday. Two lower temperature periods can be scheduled.
The schedule repeats every week.
Prim red °C -5
Here you can set how many degrees the room temperature is to be lowered during
the lower temperature periods. NB: –5 means that the room temperature is lowe
red 5°C below the ordinary temp. If the room sensor is not included in operation,
the lowering is applied to the primary flow temperature. Rule of thumb: a 3–4°C
lower primary flow temperature gives around 1°C lower room temp in a normal
system.
WeekProgram or Block
Scheduling is set under these menus, see next section.
Stored oper data
Total Operation h
h
El heat kWh
0
Max prime °C
42
Night reduction
►
Activated
Yes/No
Typ
WeekProgram
Prim red °C
-5
WeekProgram/Block