1. Important to
remember!
Check the following in particular on delivery and installation:
1.1 Transportation
• Transport the heat pump to the installation location before removing the
packaging. Move the product using one of the following means:
- Fork-lift truck
- Lifting strap around the pallet.
NB:
Can only be used with the packaging on.
• The heat pump must be transported and stored upright.
1.2 Positioning
• Remove the packaging and check before installation that the product
has not been damaged in transit. Report any transport damage to the
carrier.
• Place the product on a solid foundation, preferably concrete.
If the heat pump needs to be placed on a soft carpet, base plates
must be placed under the adjustable feet.
• Remember to leave an access and service area of at least 1 metre in
front of the heat pump.
• The heat pump must not be placed below floor level.
• Avoid placing the heat pump in rooms where the walls are of lightweight
design, as people in the adjoining room may be disturbed by the
compressor and vibrations.
1.3 Recycling
• The packaging must be deposited at a recycling station or with the
installation engineer for correct waste management.
• Obsolete products must be disposed of correctly and transported to a
waste station or distributor/retailer offering this service.
Disposal of the product as household waste is not permitted.
• It is very important that the product’s refrigerant, compressor oil and
electric/electronic components are disposed of correctly.
1.4 After commissioning
• The installation engineer advises the property owner on the design and
servicing of the system.
• The installation engineer fills in a checklist and contact information – the
customer and installation engineer sign the list, which the customer
keeps.
!
The heat pump
must be transported
and stored upright.
Summary of Contents for 588600001
Page 16: ...16 CTC EcoPart 600M CTC EcoPart 616M UPML XL GEO 25 125 130 PWM 1 x 230 V 50 60 Hz...
Page 26: ...26 CTC EcoPart 600M 7 4 Wiring diagrams 7 4 1 Cooling module A3...
Page 27: ...27 CTC EcoPart 600M...
Page 28: ...28 CTC EcoPart 600M 7 4 2 Cooling module A4...
Page 29: ...29 CTC EcoPart 600M 7 4 3 Connection box 400 V 3N...
Page 34: ...34 CTC EcoPart 600M...
Page 35: ...35 CTC EcoPart 600M...