![CTC Union 588600001 Installation And Maintenance Manual Download Page 24](http://html1.mh-extra.com/html/ctc-union/588600001/588600001_installation-and-maintenance-manual_2693331024.webp)
24
CTC EcoPart 600M
1. System disconnected from power.
2. Energise the control (EcoLogic Pro or
EcoZenith i550 Pro) as well as the CTC EcoPart 600M to
be numbered as Heat Pump 2 (A2).
3. Wait approx 2 minutes until the heat pump is visible in
the Operational Info menu.
4. Go to Advanced/Settings/Heat pump 2 and line
“Select/Rename Heat pump (M)”. Press OK.
5. Press the arrow up until (A1)* is displayed. Press OK.
After pressing OK, (A1)* disappears and the “Select/
Rename Heat Pump (M)” line darkens.
*
In this example, we have assumed that the heat pump
is called A1, which is the factory default. If the heat
pump has already been renumbered, then select this
number instead.
7.2.1 Defi ne number of heat pumps
Define the heat pumps in the controlling product’s display
under: "Advanced/Define system/Heat pump".
Set the heat pumps contained in the system to position
"On".
Example of a system with 3 heat pumps.
7.3 Connecting the control system
7.2.2 Numbering CTC EcoPart 600M
A1
A1
A1
A1
A1
A1
35
°C
40
°C
50
°C
35
°C
Operation
Heat pump 2
Compressor Permitted
Cont. brine pump on
No
Compressor stop at brine °C
-5
Brine pump on 10 days
Off
Select /Rename Heatpump
Heat pump 2
Compressor Permitted
Cont. brine pump on
No
Compressor stop at brine °C
-5
Brine pump on 10 days
Off
Select /Rename Heatpump
A1
Def. Heat pump
Heat pump 1
On
Heat pump 2
On
Heat pump 3
On
Heat pump 4
Off
Heat pump 5
Off
Heat pump 6
Off
Heat pump 7
Off
Heat pump 8
Off
Heat pump 9
Off
Heat pump 10
Off
Flow/level switch
None
Summary of Contents for 588600001
Page 16: ...16 CTC EcoPart 600M CTC EcoPart 616M UPML XL GEO 25 125 130 PWM 1 x 230 V 50 60 Hz...
Page 26: ...26 CTC EcoPart 600M 7 4 Wiring diagrams 7 4 1 Cooling module A3...
Page 27: ...27 CTC EcoPart 600M...
Page 28: ...28 CTC EcoPart 600M 7 4 2 Cooling module A4...
Page 29: ...29 CTC EcoPart 600M 7 4 3 Connection box 400 V 3N...
Page 34: ...34 CTC EcoPart 600M...
Page 35: ...35 CTC EcoPart 600M...