![CTC Union 588600001 Installation And Maintenance Manual Download Page 10](http://html1.mh-extra.com/html/ctc-union/588600001/588600001_installation-and-maintenance-manual_2693331010.webp)
10
CTC EcoPart 600M
3. Technical data
3.1 Table CTC EcoPart 612M
EcoPart 612M
588600001
400 V 3N~ 50 Hz
kW
5.8
A
2.3
A
9.7
A
16 / 13
IP X1
kg
2.4
ton
4.258
MPa (bar)
3.1 (31)
kg
170 (188 )
mm
673 x 596 x 775
dB(A)
39/41
HP Keymark Cert. No.
012-073
l
4.1
°C
-5 / +20
bar
0.2 / 3.0
l/s
0.29
l/s
0.39
kW
11.8
@ 0/35 | 0/45 | 0/55
kW
6.08 I 5.68 I 5.24 @50 rps
@ 0/35 | 0/45 | 0/55
kW
1.27 I 1.54 I 1.78 @50 rps
COP
1)
@ 0/35 | 0/45 | 0/55
-
4.78 I 3.68 I 2.95 @50 rps
@ 5/35 | 5/45 | 5/55
kW
7.1 I 6.65 I 6.36 @50 rps
COP
1)
@ 5/35 | 5/45 | 5/55
-
5.62 I 4.26 I 3.57 @50 rps
SCOP 0/35 Pdesign cold climate
2)
Pdesign = 11 kW, SCOP = 5.5
SCOP 0/55 Pdesign cold climate
2)
Pdesign = 7 kW, SCOP = 4.3
SCOP 0/35 Pdesign average climate
2)
Pdesign = 10 kW, SCOP = 5.4
SCOP 0/55 Pdesign average climate
2)
Pdesign = 7 kW, SCOP = 4.1
°C
100
l/s
0.28
l/s
0.56
Electrical data
CTC No.
Electrical data
Rated power
Max starting current
Compressor max operating current
Max / min fuse rating
Enclosure class (IP)
Other data
Refrigerant quantity (R407C, fluorinated greenhouse gas GWP
1774)
CO
2
equivalent
Interrupt value switch HP
Weight
(packaged weight)
Dimensions
(depth x width x height)
Noise level (L
WA
) @ B0 and W35/55 in compl.w.EN12102
Brine system
Water volume (V)
Brine system min/max temp (TS)
Brine system min/max pressure (PS)
Brine system min flow, ∆t = 5 K
Brine system nominal flow, ∆t = 3 K @50 rps
Pump capacity
Refer to diagram in section
Brine system pump
The products are not covered by the periodical check for leaking refrigerant.
Operational data for heat pump
Max rated output
Rated output
1)
Input power
1)
Output
1)
1)
EN14511:2018
2)
SCOP according to FprEN14825
3)
At ∆t = 10 K and 0/35°C heat pump operation.
4)
At ∆t = 5 K and 0/35°C heat pump operation.
Heating medium system
Max temperature heat carrier (TS)
Heating carrier system, min flow
3)
Heating carrier system, nominal flow
4)
Pump capacity
Refer to diagram in section
Installation
Summary of Contents for 588600001
Page 16: ...16 CTC EcoPart 600M CTC EcoPart 616M UPML XL GEO 25 125 130 PWM 1 x 230 V 50 60 Hz...
Page 26: ...26 CTC EcoPart 600M 7 4 Wiring diagrams 7 4 1 Cooling module A3...
Page 27: ...27 CTC EcoPart 600M...
Page 28: ...28 CTC EcoPart 600M 7 4 2 Cooling module A4...
Page 29: ...29 CTC EcoPart 600M 7 4 3 Connection box 400 V 3N...
Page 34: ...34 CTC EcoPart 600M...
Page 35: ...35 CTC EcoPart 600M...