8
You can configure the Rondomat 3S as follows:
1. Press and hold both the
Water plus button
and
Water minus button
.
The
menu option
is shown in the left display (
Water setting display
).
The
relevant value
is shown in the right display (
Feed setting display
).
2. Briefly press the
Water plus button
and
Water minus button
to toggle between the
individual menu options. The value shown can be changed by briefly pressing the
Feed plus button
and
Feed minus button
.
3. Set the desired options:
Option 1
: Set the pause time in seconds (value range: 1 to 99).
Option 2
: Set the sensor sensitivity (value range: 1 to 99). Lower values
increase the sensor sensitivity whereas higher values decrease its sensitivity.
Option 3
: Set the factory settings. Restore the default values (see below) by
pressing and holding the
Feed plus button
. A display test then follows in which
all displays repeatedly display the values 0 to 9 in ascending order. Press
Water plus button
or
Water minus button
to end the test.
Option 4
: Readout of the program version.
Option 5
: Readout of the measured sensor value (only for service purposes).
Option 6
: Readout of the measured sensor gradient (only for service
purposes).
If no button is pressed for a considerable time (approx. 30 sec.), the menu is
exited automatically
The default factory settings are:
Water: 0
Feed: 1
Pause time: 10 sec.
Sensor sensitivity: 10