ENVIRONMENTAL PROTECTION
Recycle raw materials instead of disposing as waste. The machine, accessories and
packaging should be sorted for environmental-friendly recycling. Do not throw used batteries
into waste, fire or water but dispose of in an environmentally friendly manner according to
the applicable legal regulations.
SPECIFICATIONS
Description
56-DGT2
56-DGT10
Telescope
Overall Length
155mm (6.1")
155mm (6.1")
Objective aperture
45mm (1.77")
45mm (1.77")
Magnification
30X
30X
Image
Erect
Erect
Field of view
1° 30'
1° 30'
Resolving power
2.5"
2.5"
Minimum focus
1.3M (53")
1.3M (53")
Stadia Ratio
100 to 1
100 to 1
Stadia constant
0
0
ELECTRONIC ANGLE MEASUREMENT
Method
Incremental
Incremental
Minimum reading
5/1(1mgon/0.5 mgon)
5"/10" (3/5 mgon)
Accuracy**
2” (0.5 mgon)
5" (1.5 mgon)
Diameter of circle
82mm (3.22")
82mm (3.22")
ILLUMINATION
Display & Reticle
Display & Reticle
OPTICAL PLUMMET
Magnification
3X
3X
Field of view
5°
5°
Focusing range
0.5 M to infinity (20" to infinity) 0.5 M to infinity (20" to infinity)
LEVEL VIAL SENSITIVITY
Plate vial
30" per 2mm
30" per 2mm
Circular vial
8' per 2mm
8' per 2mm
18 • DGT2 - DGT10