SIGNATURE 2 SERIES 

           Troubleshooting Guide

SYMPTOM

PROBABLE CAUSE

CORRECTION

1. Reactr Fails to 

    Regenerate 

    Automatically

Power supply plugged into 
intermittentent or dead power source

Connect to constant power source

Improper control valve 
programming

Reset program settings

Defective power supply

Replace power supply

Defective Drive motor

Replace motor

2. Regeneration at 

    Wrong Time

Time of day improperly set, due to 
power failure

Reset time of day programming and 
install 9-volt battery.

Regeneration time set improperly

Reset regeneration time programming

3. Poor Water Quality

Check items listed in #1 and #2

Bypass valve open

Close bypass valve.

Channeling

Check for too slow or high service 
flow. Check for media fouling.

Water is not getting enough aeration

Check for air draw at air inlet check 
valve while well pump is running. 
Clean air inlet check valve, reactr 
nozzle and float assembly.

4. Loss of Water Pressure

Scaling / fouling of inlet pipe

Clean or replace pipline. Pretreat to 
prevent.

Fouled media

Clean media. Pretreat to prevent. 

Improper backwash setting

Backwash more frequently

5. Continuous Flow to        

    Drain

Foreign material in control valve

Call dealer. Clean valve and replace 
piston and seals

Internal control leak

Same as above.

Valve jammed in backwash, brine or 
rapid rinse position

Same as above.

Motor stopped or jammed

Check for jammed piston. Replace 
piston and seals. Replace motor if 
motor is unresponsive. 

Error Codes

 There are five (5) error codes which could indicate a possible problem with the control valve:

 

Error 2 -

  Valve is searching for homing slot.

                            Allow valve to run until homing slot is found or new error code appears.

 

Error 3 -

  No encoder slots are being seen.

 

 

    Check encoder connection. If encoder is connected. Check valve body for debris 

 

 

    and replace seals. Inspect piston and replace if worn.

 

Error 4 -

  Unable to find homing slot.

 

 

    Check encoder wheel for debris.

 

Error 5 -

  Motor overload.

 

                Check valve body for debris. Replace seals. Inspect piston and replace if worn. 

                            Check motor operation and replace motor if unresponsive.

 

Error 6 -  

No power to motor. Check motor connections, replace motor if unresponsive.

16

Summary of Contents for REACTR RF15

Page 1: ...SIGNATURE 2 SERIES Signature 2 Series Reactr Installation Operation Manual...

Page 2: ...ontrol Start Up Procedures Page 7 Utilizing Bluetooth Page 9 Master Programming Page 10 Powerhead Assembly Page 11 Valve Body Assembly Page 12 Manifold Breakdown Page 13 Bypass Assembly Page 14 Additi...

Page 3: ...bricant for all control valves Dow Corning 7 Release Compound is used in the manufacture of Chandler Systems control valves Part LT 150 Sealants Pipe dope and liquid thread sealers may contain a carri...

Page 4: ...area of direct sunlight or where freezing temperatures may occur See Installation Diagrams for proper placement and plumbing connections Installation 4 GROUNDED UNSWITCHED 115 VOLT OUTLET AIR INLET AI...

Page 5: ...sired location A Remove the control valve by unscrewing from the tank Do not fill through dome hole if installed B Use cap provided to place over top of distributor tube to prevent material from enter...

Page 6: ...te Where the drain line is elevated above the control valve or exceeds 20 feet in length 3 4 I D drain line tubing should be used Electrical Connection 1 Connect the power supply to the control valve...

Page 7: ...ver occur 3 Default setting is 6 days for filters 5 To Exit Main Menu press the Menu Enter button Note If no buttons are pressed for 60 seconds the Main Menu will be exited automatically 7 Control Sta...

Page 8: ...turn and finish the cycle where it left off prior to the power interruption When used without battery back up during a power failure the unit stops at its current point in the regeneration position an...

Page 9: ...If the valve device is a BTLE valve and it has a password other than the default password the first time you connect to it the app will ask you to enter the password After entering it the first time...

Page 10: ...ge the digits with the Set Change button and accept with the Menu Enter button After the entire display flashes press the Menu Enter button to move to the next menu item 2 Regeneration Cycle Step Time...

Page 11: ...Plate 20001X005 1 8 Lower Front Base For Cover 20111X002 1 9 Motor 20016X006 1 10 Lower Back Base for Cover 20111X003 1 11 Valve Cover 20111X000 1 12 Piston Screw 20001X003 1 13 Screw SC10 3 14 Screw...

Page 12: ...M PVC 20251X262 1 Flow Control Assy 6 0 GPM PVC 20251X263 1 Flow Control Assy 7 0 GPM PVC 20251X264 1 7 Drain Flow Fitting 90 Elbow 1 2 NPT X 1 2 20251X255 1 8 Drain Retainer 20001X214 1 9 O Ring Brin...

Page 13: ...OD x 1 4 ID x 12 VENT TUBE 1 12 65555X230 1 4 NPT PLASTIC PIPE PLUG 2 1 2 5 4 6 11 10 9 8 12 3 7 Ref Description Part Number Qty 0 Complete Manifold Assy w Float 65555X330 1 1 Screw 1 4 X 3 1 2 SS Ph...

Page 14: ...SIGNATURE 2 SERIES Bypass Assembly Ref Description Part Qty 1 Plastic Bypass Valve Assembly 20561X292 1 2 Bypass Valve 3 4 Stainless Steel 20561X270 1 Bypass Valve 1 Stainless Steel 20561X283 1 14 1 2...

Page 15: ...powerhead mounting screws The entire powerhead assembly will now lift off easily 4 Remove piston retaining plate screws 5 Pull upward on end of piston yoke until assembly is out of valve 6 Inspect th...

Page 16: ...lace pipline Pretreat to prevent Fouled media Clean media Pretreat to prevent Improper backwash setting Backwash more frequently 5 Continuous Flow to Drain Foreign material in control valve Call deale...