Form I-RA/D 350/500, Page 34
Outer
Cylinder
Inner
Cylinder
Maintenance
Procedures
Continued
Pre-Heater Box
Pre-Heater
Controls
2. Remove the Pre-Heater from the Pre-Heater Box
• Remove the corner panel from the end of the box. The pre-heater
controls are visible.
• Disconnect the fuel lines at the inlet and outlet connections.
NOTE: There will be oil in the lines.
• Disconnect wires to the temperature controls.
• Disconnect the heating element wires.
• Remove the screw that attaches the pre-heater front support to
the bottom of the box.
• Slide the cylindrical aluminium pre-heater out of the box.
3. Clean the Pre-heater
• Place the pre-heater in a vice and carefully remove the outer
cylinder and the “O” ring. NOTE: There will be oil in the pre-
heater.
• Clean the inner section with a cloth and degreaser such as
carburetor cleaner. Be careful not to “clean” the electrical
controls. Do not immerse in cleaning fluid.
• Clean the outer portion of the cylinder with degreaser.
Cleaning Exte
-
rior Surfaces
of Combustion
Chamber, Heat
Exchanger and
Air Moving
Device
WARNING: Turn off
the electric power
before cleaning
heater.
4. Reassemble the Pre-Heater and the heater.
• Check the “O” ring. If a new one is required, replace with P/N
132224.
• Reassemble the cylinder pieces with “O” ring in place.
• Slide the pre-heater in the box and attach the front support.
Reconnect the wires and the fuel lines and close the corner
cover.
• Replace the burner assembly and reconnect the ignition
controller.
To gain access to the front side of the combustion chamber/heat ex-
changer, remove the discharge louvers.
To access the air moving device, disconnect the wiring in the fan/blower
junction box and the flexible conduit.
• Use a stiff brush and a shop vacuum to clean the accumulated
dust and dirt from the exterior surface of the combustion chamber
and the heat exchanger.
• Clean the air moving device (fan or blower). Use a brush and a
shop vacuum, being careful not to bend or damage either the
fan blade or the blower wheel. Use a shop vacuum to remove
accumulated dirt from the motor.
• Replace the air moving device and the discharge louvers.
• Connect the flexible conduit and wiring.
Check operation.
Cleaning ensures maximum efficiency and eliminates the possibility of
the heater cycling on the limit switch from lack of air flow.
Summary of Contents for RA 350
Page 48: ...Form I RA D 350 500 Page 48 Wiring Diagram 147351 for Models RA RAD 350 Appendix...
Page 49: ...Form I RA D 350 500 P N 131090R12 Page 49...
Page 51: ...Form I RA D 350 500 P N 131090R12 Page 51...
Page 53: ...Form I RA D 350 500 P N 131090R12 Page 53...
Page 55: ...Form I RA D 350 500 P N 131090R12 Page 55...