No.
DISPLAY
MEANING
10
fume motor
Fume motor not working: call for an authorized engineer
11
mixing auger
The mixing auger of the burner is not turning: check for any obstructions in the fuel pipe
or call for an authorized engineer
12
crucible
The burner crucible does not rotate: clean the burner and restart or call for an author-
ized engineer
20
1 res. start. KO
One of the heating elements is not working: call for an authorized engineer
21
2 res. start. KO
Both heating elements are not working: call for an authorized engineer
22
res. fault
The heating elements are always powered: call for an authorized engineer
30
fume probe
Fume temperature probe interrupted or not connected: call for an authorized engineer
32
boiler probe
Temperature probe interrupted or not connected: call for an authorized engineer.
33
hot water sensor
Hot water temperature probe interrupted or not connected: call for an authorized engineer
40
auger sensor
Fuel auger safety thermostat triggered: clean the stove interior, reset the thermostat
and restart the stove.
41
H2O thermostat
Stove safety thermostat triggered: clean the stove interior, reset the thermostat and re-
start the stove.
50
pressure switch
Air pressure switch not working: call for an authorized engineer
51
H2O pressure
Stove water pressure lower than 0.5 bar: load water onto the system or call for an
authorized engineer
60
black out
No power: clean the burner and restart it
62
Communication error
Internal error of the electronic board: call for an authorized engineer
70
failed ign.
Failed ignition: clean the burner and restart it
71
flame OFF
The flame went OFF during operation: clean the burner and restart
72
fume overheating
Combustion fume overheating: clean every part of the stove and restart
73
continuous loading
Pellet loading motor operation fault: call for an authorized engineer
80
filling
Fuel tank filling did not take place in the preset time: check the loading auger and that
there is fuel. Call for an engineer
82
puffer probe
Temperature probe interrupted or not connected: call for an authorized engineer
100
system cycle
Internal error of the electronic board: switch off and restart the stove
101
service
Stove maintenance warning: call for an authorized engineer
To reset the stove operation, keep button
SET
pressed for 5 seconds.