![CS THERMOS Murano 15/18 Instructions Manual Download Page 38](http://html1.mh-extra.com/html/cs-thermos/murano-15-18/murano-15-18_instructions-manual_2692459038.webp)
38
cod. 6118005 ed. 06-2021
8.11 ELECTRONIC BOARD
MSC
FUMI T. AMB SC-SA
+ - CRG + -
+
G
B-
A+
S2
S1
SANIT AUX P. H2O
-
+
T. H2O
T. COC
PRESS COCLEA
CROG.
MISC. CIRC-AMB
FUMI
V. AMB
FN
AC
C.
1A
CC
. 2
NC.
NA
.
DE
V
If you are using a water heater, connect the probe supplied.
Take care with the connection of the room thermostat that will need to be with a “clean contact”,
to avoid damaging the electronic board.
FUME
FAN
ENCODER
HEATING
FAN 1
FUME
MOTOR
CRUCIBLE
AUGER
MOTOR
MIX
AUGER
MOTOR
CIRCULATOR /
HEATING
FAN 2
FUME/STOVE
SAFETY
THERMOSTAT
PELLET LOADING
AUGER
MOTOR
AUGER
SAFETY
THERMOSTAT
AIR PRESSURE
SWITCH
ELEC
TRIC
AL
RESIST
ORS
DIVER
TER
VAL
VE
SUPPL
Y
230V - 50H
z
FUSE
DISPLA
Y
PR
OGR
AMMING
POR
T
PROBE
S2
PROBE
S1
HOT WATER
SENSOR
ROOM SENSOR /
STOVE SENSOR
MIX
AUGER
SENSOR
ROOM
THERMOSTAT
COMMUNICATION
BUS
CRUCIBLE
SENSOR
FUME
PROBE
AUX
CONTACT
WATER
PRESSURE
SWITCH