![CS THERMOS Murano 15/18 Instructions Manual Download Page 37](http://html1.mh-extra.com/html/cs-thermos/murano-15-18/murano-15-18_instructions-manual_2692459037.webp)
37
cod. 6118005 ed. 06-2021
8.10 ELECTRICAL CONNECTIONS
On the back of the stove there is a socket for the electrical connection. To get power, just connect the cable supplied to
the unit as well as to a wall schuko socket.
Before connecting it, make sure the thermal circuit breaker is OFF.
2
OFF
1
CONNECTION OF ROOM THERMOSTAT, HOT WATER SENSOR, PUFFER PROBE (OPTIONS)
It is possible to connect a room thermostat (option) that detects the temperature in the area where it is installed and that
enables and disables the operation of the stove.
S2
S1
SANIT AUX P. H2O
-
+
S2
S1
SANIT AUX P. H2O
-
+
MSC
FUMI T. AMB SC-SA
+ - CRG + -
The room thermostat must have
a minimum activation ΔT of 1°C.
To install the thermostat or one or
more sensors, use the two cable
glands on the back of the stove
and connect them to the electri-
cal board.
Room
thermostat
Hot water
sensor
Puffer
probe