Crystal Vision
Card edge operation
SW803 3G User Manual R1.4
14
01/09/2016
Saving and recalling presets
Unlike a macro, a preset is a snapshot of the state of every crosspoint. Up to fifteen
presets can be saved and recalled at any time.
To save a snapshot of all crosspoint assignments as a preset enter the Save Presets menu
and select the desired location 1-15 and press the ENTER button to assign that location.
Press ENTER a second time to action the save. A successful save will be indicated by the
word ‘Done’ appearing on the display.
Note:
Any previously saved crosspoint assignment in a location will be overwritten by the new
configuration.
To recall a preset enter the Recall Presets menu and select the desired location 1-15. Press
the ENTER button to select that location. Press ENTER a second time to action the recall.
A successful recall will be indicated by the word ‘Done’ appearing on the display.
Tip:
If necessary view the routing table to confirm that the required connections have been set.
Saving and recalling macros
A macro is a batch of crosspoint assignments, which are changed together and unlike a
preset will only affect that batch of crosspoints, any crosspoints outside of the batch will
remain unaffected when the macro is recalled.
To build a macro select the Macro Record menu and press the ENTER button. This will
cause the Macro Record text to change from normal text to an italic font. Press the up
arrow [
] and navigate to the routing menus where the desired assignment can be made.
Navigate to the Macro Save menu and select a location where the macro is to be saved.
Save the macro.
To recall a macro enter the Recall Macro menu and select the desired location 1-15. Press
the ENTER button to select that location. Press ENTER a second time to action the recall.
A successful recall will be indicated by the word ‘Done’ appearing on the display.
Tip:
If necessary view the routing table to confirm that the required connections have been set.
Note:
When reassigning routing, it is not necessary to disturb the existing routing. This is achieved
by leaving the new routing unasserted. See Routing.
GPI control
The SW803 3G may be controlled via GPI lines connected to the rear of the frame in
which the module is used. GPI control is limited to recalling stored presets or macros.
GPI control cannot be used at the same time as the SW808 Controller panel as both use
the same physical control lines. Please refer to the Installation chapter for more
information on using GPIs.
To enable GPI control select GPI control Enable.