Crystal Vision
General Purpose Interface
The 16 user preset configurations can be recalled using binary notation.
Preset
Bit 8
Bit 4
Bit 2
Bit 1
Preset Bit 8 Bit 4 Bit 2
Bit 1
1
H
H
H
H
9
L
H
H
H
2
H
H
H
L
10
L
H
H
L
3
H
H
L
H
11
L
H
L
H
4
H
H
L
L
12
L
H
L
L
5
H
L
H
H
13
L
L
H
H
6
H
L
H
L
14
L
L
H
L
7
H
L
L
H
15
L
L
L
H
8
H
L
L
L
16
L
L
L
L
2U frame GPI connections
GPI lines ‘a’ to ‘f’ of each card connect to two of four rear remote connectors as
follows:
Slot no. ‘a’ pin
‘b’ pin
‘c’ pin
‘d’ pin
‘e’ pin
‘f’ pin
1
8 (1)
9 (1)
18 (1)
26 (1)
19 (2)
20 (2)
2
7 (1)
16 (1)
17 (1)
25 (1)
10 (2)
11 (2)
3
8 (3)
9 (3)
18 (3)
26 (3)
19 (4)
20 (4)
4
7 (3)
16 (3)
17 (3)
25 (3)
10 (4)
11 (4)
5
5 (1)
6 (1)
15 (1)
24 (1)
1 (2)
2 (2)
6
4 (1)
14 (1)
13 (1)
23 (1)
3 (2)
4 (2)
7
5 (3)
6 (3)
15 (3)
24 (3)
1 (4)
2 (4)
8
4 (3)
14 (3)
13 (3)
23 (3)
3 (4)
4 (4)
9
3 (1)
12 (1)
22 (1)
21 (1)
12 (2)
13 (2)
10
10 (1)
11 (1)
19 (1)
20 (1)
21 (2)
22 (2)
11
3 (3)
12 (3)
22 (3)
21 (3)
12 (4)
13 (4)
12
10 (3)
11 (3)
19 (3)
20 (3)
21 (4)
22 (4)
Table shows pin number (remote number)
Note:
Remote 1 and Remote 3 are 26-way high-density D-Type female
sockets. Frame ground is pin 2 and +5V @500mA is pin 1 in each
case.
Remote 2 and Remote 4 are 26-way high-density D-Type male plugs
and frame ground is pin 6 in each case and +5V @500mA is pin 15 on
Remote 2.
Note: The +5V output is protected by self-resetting thermal fuses,
which limit the total output current available from Remotes 1-4 to
approximately 1A.
Q-Down-AG 3G/ATG 3G User Manual R2.1
12
11 July 2019