Crystal Vision
Hardware
installation
5
26/02/2007
2 Hardware installation
The ENDAC single height module uses the RM01, which will fit into all Crystal Vision
rack frames. All modules can be plugged in and removed while the frame is powered
without damage.
The ENDAC can also be used with several other rear modules such as the RM02 and
RM18 but at reduced packing density.
2.1 Rear modules and signal I/O
The Indigo 4 4U frame will house up to 24 single height modules with up to three power
supplies. The FR2AV and Indigo 2 2U frames will house up to 12 single height modules
and dual power supplies. The FR1AV and Indigo 1 1U frames will house six single height
modules and a single power supply. The DTBAV and Indigo desk top boxes both have a
built-in power supply and will house up to two single height modules.
Note:
For details of fitting rear connectors please refer to the appropriate frame manual
Rear module connections with RM01
The RM01being a single height module will allow maximum packing density with the
maximum number of outputs available.
RM01 rear module connector
Description
RM01
•
24 ENDAC modules per
Indigo 4 frame
•
12 per FR2AV or Indigo
2 frame
•
Six per FR1AV or Indigo
1 frame
•
2 per Indigo DT
•
All frame slots can be
used
BNC
I/O assignment
R/V PAL/NTSC OUT
Component R / V or composite output (link selectable)
SDI IN
Serial digital input
SDI LOOP
Reclocked SDI input loop-through
Y/ G PAL/NTSC OUT
Component G / Y, YC-Y or composite output (link selectable)
C/B/U PAL/NTSC OUT
Component B / U, YC-C or Composite output (link selectable)
PAL/NTSC OUT
Composite Output