Crystal Vision
Trouble
shooting
15
26/02/2007
The message shows that an ENDAC has been selected with the version of software on the
module as Vv2.03.
The ENDAC home menu
Updating the display
The values displayed on an active front panel are only updated when an adjustment is
made and when changing menu level. If mode changes occur through the use of
Statesman, card edge controls or through automatic response to the input video signal, the
text displayed on the active front panel will not be updated immediately. If necessary,
press CAL to update the display.
The ENDAC menu structure
The main top-level menu is obtained by pressing the F1 HOME menu. Menu keys are
illuminated when active and when further menus are available.
Pressing the Function keys F2-3 accesses the ENDAC's sub menus. When a sub menu has
been selected, further options can be accessed by further use of the function buttons.
Where adjustments are available rotating the shaft will then make the required change. An
adjacent LED illuminating indicates an active key. All key presses and numeric value
changes are implemented immediately.
The following chart shows the available ENDAC menus. The actual menus available may
vary slightly as software is updated.