TECHNICAL DATA
GAS TYPE:
NATURAL GAS
GAS PRESSURE:
20mbar
CONNECTION
8mm TUBE
INJECTOR manual control: CAT 82/460 BRAY
INJECTOR remote control: CAT 82/440 BRAY
HEAT INPUT 6.9kW HIGH
4.1kW LOW
CAT 1
2H
DATA BADGE ON FRONT BOTTOM SECTION OF APPLIANCE
IMPORTANT NOTES
THIS APPLIANCE IS FITTED WITH AN ATMOSPHERE SENSING DEVICE
AND CAN ONLY BE FITTED IN CONJUNCTION WITH THE FOLLOWING
FLUES.
CONVENTIONAL BRICK OR STONE CHIMNEY.
A PRE CAST FLUE CONFORMING TO BS 1289 PT 1
OR A METAL FLUE BOX CONFORMING TO BS715
A NON COMBUSTIBLE HEARTH MUST BE PROVIDED TO COMPLY WITH
THE BUILDING REGULATIONS OR A SUITABLE PROPRIETARY FIRE
SURROUND WITH 100 DEGREES C RATING.
THE CHIMNEY OR FLUE (UNLESS NEW) MUST BE SWEPT BEFORE
INSTALLATION, IF IT HAS BEEN USED FOR SOLID FUEL
INSTALLER
THIS APPLIANCE MUST BE INSTALLED BY A COMPETENT PERSON
IE. A C.O.R.G.I. REGISTERED INSTALLER IN ACCORDANCE WITH THE
CURRENT EDITION OF THE GAS SAFETY (INSTALLATION AND USE)
REGULATIONS OR THE RULES IN FORCE. FAILURE TO DO SO COULD
LEAD TO PROSECUTION.
VENTILATION GREAT BRITAIN
NO SPECIAL VENTILATION BRICKS OR VENTS ARE NORMALLY
REQUIRED INTO THE ROOM CONTAINING THE APPLIANCE, PROVIDED
NORMAL ADVANTAGEOUS ROOM VENTILATION EXISTS, THE
INSTALLER MUST SATISFY THIS POINT BY A MANDATORY SPILLAGE
TEST.
IRELAND.
PURPOSE PROVIDED VENTILATION MUST BE PROVIDED AND
MUST HAVE A MINIMUM FREE AREA OF 100CM
2