ISSUE 2
16
USERS INSTRUCTIONS FOR JEWEL GAS APPLIANCE
YOUR JEWEL GAS APPLIANCE IS A DECORATIVE LIVE FUEL EFFECT
GAS FIRE ,DUE TO ITS NEWNESS THE FIRE MAY GIVE OFF SLIGHT
SMELL FOR A SHORT PERIOD AFTER INSTALLATION .THIS IS QUITE
NORMAL AND WILL DISAPPEAR AFTER A FEW HOURS OF OPERATION.
THE APPLIANCE TO WHICH THESE INSTRUCTIONS APPLY MUST BE
INSTALLED BY A COMPETENT PERSON(EG. A C.O.R.G.I MEMBER IN
ACCORDANCE WITH THE CURRENT EDITION OF THE GAS SAFETY
INSTALLATIONS AND USE REGULATIONS OR THE RULES IN
FORCE)APPROVED BY THE HEALTH AND SAFETY EXECUTIVE AND
MUST BE IN ACCORDANCE WITH THE INSTALLATION AND SERVICING
INSTUCTIONS SUPPLIED.
SERVICING SHOULD BE CARRIED OUT REGULARLY BY A COMPETENT
PERSON ( EG A C.O.R.G.I MEMBER)IN ACCORDANCE WITH THE CURRENT
EDITION OF THE GAS SAFETY (INSTALLATION AND USE) REGULATIONS
OR THE RULES IN FORCE.TO ENSURE THE CORRECT AND SAFE
OPERATION OF THE APPLIANCE .DEBRIS SHOULD ALSO BE REMOVED
FROM BEHIND THE APPLIANCE AT REGULAR INTERVALS.
BEFORE INSTALLATION OF THE APPLIANCE THE CHIMNEY MUST BE
SWEPT AND THEN INSPECTED REGURLARLY TO ENSURE THAT IT
REMAINS FREE OF OBSTRUCTION.
A FIRE GUARD COMPLYING TO BS8423 ,MUST BE FITTED IF THE ROOM
WILL BE OCCUPIED BY YOUNG CHILDREN THE ELDERLY ,OR INFIRM
PEOPLE. ON NO ACCOUNT MUST ANY RUBBISH BE THROWN ON TO THE
FIRE OR THE LAYOUT OF THE FIREBED DISTURBED.
OPERATING INSTRUCTIONS.
THE APPLIANCE DATA BADGE IS POSITIONED ON THE FRONT BOTTOM SECTION
OF THE APPLIANCE AND CARIES THE CONTROL KNOB POSITIONS.THE FULL
LIGHTING PROCEDURE IS AS FOLLOWS.
1.PUSH CONTROL KNOB IN AS FAR AS POSSIBLE ON GAS CONTROL
2.TURN KNOB ANTICLOCKWISE TO IGNITION POSITION STILL KEEPING KNOB IN
AS FAR AS POSSIBLE.
3.THE IGNITION BUTTON WILL IGNITE THE PILOT WITH THIS OPERATION
KEEP
THE KNOB PRESSED IN FOR 15 SECONDS.
IF THE PILOT FAILS TO LIGHT TURN
THE CONTROL KNOB CLOCKWISE TO THE OFF POSITION, WAIT 3 MINUTES AND
REPEAT THE PROCEDURE
4.WHEN THE PILOT FLAME IS ALIGHT THE CONTROL KNOB SHOULD BE ALLOWED
TO SPRING OUT SLIGHTLY.TURN THE KNOB FULLY ANTICLOCKWISE TO THE HIGH
POSITION.THE PILOT FLAME WILL THEN IGNITE THE MAIN BURNER.THE PILOT
FLAME CAN BE VIEWED TO THE RIGHT OF THE FIRE JUST BEHIND THE FRONT
LOG SET
5.THE APPLIANCE CAN BE ADJUSTED BETWEEN HIGH AND LOW BY MOVING THE
CONTROL KNOB TO SUIT,THE KNOB WILL NEED TO BE DEPRESSED SLIGHTLY TO
MOVE FROM LOW HIGH AND IGNITION.
6.TO TURN THE FIRE OFF,DEPRESS THE KNOB SLIGHTLY AND TURN IT TO
PILOT POSITION.
7.TO COMPLETELY EXTINGUISH THE FIRE DEPRESS THE KNOB SLIGHTLY AND
TURN TO OFF POSITION.
8.SHOULD THE SPARK IGNITION FAIL TO OPERATE.TURN THE CONTROL KNOB TO
THE OFF POSITION AND WAIT 3 MINUTES.TURN THE KNOB TO THE IGNITION
POSITION AND THEN LIGHT THE PILOT WITH A TAPER.”LIGHTING THE PILOT