Issue 1
17
Section 5
Users instructions
5.1 installation information
1.1 conditions of installation
It is the law that all gas appliances are installed only by a competent person
Ie: a registered installer in accordance with the current edition of the gas safety(installation
and use )regulations or the rules in force.failure to do so could lead to prosecution
The installer must be gas safe registered .
The fire may be fitted below a combustible shelf provided that the shelf is at least 200mm
above the top of the appliance and the depth of the shelf does not exceed 150mm
The fire may be installed below combustible shelves which exceed 150mm deep providing
that the clearance above the fire is increased by 15mm for each 25mm of additional
overhang in excess of 150mm
No purpose made additional ventilation is normally required for this appliance ,when
installed in G.B.
when installing in I.E.please consult document I.s 813 domestic gas installation, which is issued by
the national standards authority of Ireland.
If installing in northern Ireland please consult local building regulations
In Scotland ,please consult the current edition of the building standards regulations, issued
by the Scottish executive.any purpose made ventilation must be checked periodically to
ensure that it is free from obstruction.
If this appliance is fitted directly against a wall without the use of a fire surround or
fireplace all combustible materials must be removed from behind the trim .soft wall
coverings such as blown vinyl ,wall paper etc, could be affected by the rising hot air
scorching and /or discolouration may result ,due consideration should be made to this when
installing or decorating.
If the chimney or flue has been used previously by appliances burning fuels other than gas
they must be thoroughly swept prior to installation of this fire
The fire must be registered by your installer to gas safe
Please take time to read these instructions as you will be able to obtain the most effective
and safe operation of this appliance